介质液体微透镜的动态响应

Chih-Cheng Yang, Yih-Ching Wang, J. Yeh
{"title":"介质液体微透镜的动态响应","authors":"Chih-Cheng Yang, Yih-Ching Wang, J. Yeh","doi":"10.1109/OMEMS.2010.5672204","DOIUrl":null,"url":null,"abstract":"A dynamic response of liquid microlens using dielectric force was demonstrated using comparison between experimental and simulation results. The theoretical results of the simulation match fairly well with the experiment in liquid microlens with a diameter of 500 μm. An high speed motion camera with a speed of 3000 fps was used to capture the images of dynamic response for 500μm, 2mm and 5mm droplets in diameter, respectively. Results indicate that a viscosity strongly affects dynamic response time for 2mm droplet in diameter, but only weakly impacts on final contact angle. A propagation of wave on the droplet surface was found when 100Vrms voltage applied on microlens with a diameter of 5mm. The study may provide the basis for development of optical liquid microlens.","PeriodicalId":421895,"journal":{"name":"2010 International Conference on Optical MEMS and Nanophotonics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic response of dielectric liquid microlens\",\"authors\":\"Chih-Cheng Yang, Yih-Ching Wang, J. Yeh\",\"doi\":\"10.1109/OMEMS.2010.5672204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A dynamic response of liquid microlens using dielectric force was demonstrated using comparison between experimental and simulation results. The theoretical results of the simulation match fairly well with the experiment in liquid microlens with a diameter of 500 μm. An high speed motion camera with a speed of 3000 fps was used to capture the images of dynamic response for 500μm, 2mm and 5mm droplets in diameter, respectively. Results indicate that a viscosity strongly affects dynamic response time for 2mm droplet in diameter, but only weakly impacts on final contact angle. A propagation of wave on the droplet surface was found when 100Vrms voltage applied on microlens with a diameter of 5mm. The study may provide the basis for development of optical liquid microlens.\",\"PeriodicalId\":421895,\"journal\":{\"name\":\"2010 International Conference on Optical MEMS and Nanophotonics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Optical MEMS and Nanophotonics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OMEMS.2010.5672204\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Optical MEMS and Nanophotonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMEMS.2010.5672204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过实验与仿真结果的对比,证明了液体微透镜在介电力作用下的动态响应。在直径为500 μm的液体微透镜中,理论模拟结果与实验结果吻合较好。采用3000 fps的高速运动摄像机分别捕捉直径为500μm、2mm和5mm的液滴的动态响应图像。结果表明:黏度对直径2mm液滴的动态响应时间影响较大,对最终接触角影响较小;在直径为5mm的微透镜上施加100Vrms电压,发现波在液滴表面有传播。该研究可为光学液体微透镜的开发提供依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic response of dielectric liquid microlens
A dynamic response of liquid microlens using dielectric force was demonstrated using comparison between experimental and simulation results. The theoretical results of the simulation match fairly well with the experiment in liquid microlens with a diameter of 500 μm. An high speed motion camera with a speed of 3000 fps was used to capture the images of dynamic response for 500μm, 2mm and 5mm droplets in diameter, respectively. Results indicate that a viscosity strongly affects dynamic response time for 2mm droplet in diameter, but only weakly impacts on final contact angle. A propagation of wave on the droplet surface was found when 100Vrms voltage applied on microlens with a diameter of 5mm. The study may provide the basis for development of optical liquid microlens.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信