Yuzhe Chen, Shiwei Feng, Yamin Zhang, Xin He, Kun Bai, Xuan Li
{"title":"电子器件热测量中表面粗糙度对固定界面接触热阻的影响","authors":"Yuzhe Chen, Shiwei Feng, Yamin Zhang, Xin He, Kun Bai, Xuan Li","doi":"10.1109/ICEDME50972.2020.00017","DOIUrl":null,"url":null,"abstract":"The interfacial thermal resistance between two solid materials is usually large, but there is still no way to eliminate it nor uniform measurement standard. Therefore, in thermal measurement technology, because the surface roughness of material directly affects the interface morphology, the change of total thermal resistance caused by the thermal contact resistance (TCR) fluctuations disturbs the accuracy of internal thermal analysis of the device. We prepared samples with different surface roughness and performed thermal measurements on them, compared with the test under vacuum environment and the condition filled with thermal interface materials, respectively. We found the heat transfer mechanism at the fixed interface. More importantly, it is shown that in the interval of surface roughness Ra < 6.4, the TCR shows good consistency when filled with thermal interface materials. This result will help to quickly improve the accuracy of thermal measurement technology.","PeriodicalId":155375,"journal":{"name":"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of Surface Roughness on Thermal Contact Resistance of Fixed Interface in Thermal Measurement of Electron Device\",\"authors\":\"Yuzhe Chen, Shiwei Feng, Yamin Zhang, Xin He, Kun Bai, Xuan Li\",\"doi\":\"10.1109/ICEDME50972.2020.00017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The interfacial thermal resistance between two solid materials is usually large, but there is still no way to eliminate it nor uniform measurement standard. Therefore, in thermal measurement technology, because the surface roughness of material directly affects the interface morphology, the change of total thermal resistance caused by the thermal contact resistance (TCR) fluctuations disturbs the accuracy of internal thermal analysis of the device. We prepared samples with different surface roughness and performed thermal measurements on them, compared with the test under vacuum environment and the condition filled with thermal interface materials, respectively. We found the heat transfer mechanism at the fixed interface. More importantly, it is shown that in the interval of surface roughness Ra < 6.4, the TCR shows good consistency when filled with thermal interface materials. This result will help to quickly improve the accuracy of thermal measurement technology.\",\"PeriodicalId\":155375,\"journal\":{\"name\":\"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEDME50972.2020.00017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEDME50972.2020.00017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of Surface Roughness on Thermal Contact Resistance of Fixed Interface in Thermal Measurement of Electron Device
The interfacial thermal resistance between two solid materials is usually large, but there is still no way to eliminate it nor uniform measurement standard. Therefore, in thermal measurement technology, because the surface roughness of material directly affects the interface morphology, the change of total thermal resistance caused by the thermal contact resistance (TCR) fluctuations disturbs the accuracy of internal thermal analysis of the device. We prepared samples with different surface roughness and performed thermal measurements on them, compared with the test under vacuum environment and the condition filled with thermal interface materials, respectively. We found the heat transfer mechanism at the fixed interface. More importantly, it is shown that in the interval of surface roughness Ra < 6.4, the TCR shows good consistency when filled with thermal interface materials. This result will help to quickly improve the accuracy of thermal measurement technology.