A. De Leo, G. Cerri, P. Russo, V. Mariani Primiani
{"title":"多单极源搅拌混响室屏蔽效能测量","authors":"A. De Leo, G. Cerri, P. Russo, V. Mariani Primiani","doi":"10.23919/URSIGASS49373.2020.9232246","DOIUrl":null,"url":null,"abstract":"This paper reports the measurement of the shielding effectiveness of a metallic enclosure. The experimental environment is a reverberation chamber where the multiple monopole source stirring technique is implemented. The results are compared to the measurements in the same environment, by using a traditional mechanical stirring technique and to the anechoic scenario using numerical simulations.","PeriodicalId":438881,"journal":{"name":"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shielding Effectiveness Measurement in a Multiple Monopole Source Stirred Reverberation Chamber\",\"authors\":\"A. De Leo, G. Cerri, P. Russo, V. Mariani Primiani\",\"doi\":\"10.23919/URSIGASS49373.2020.9232246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports the measurement of the shielding effectiveness of a metallic enclosure. The experimental environment is a reverberation chamber where the multiple monopole source stirring technique is implemented. The results are compared to the measurements in the same environment, by using a traditional mechanical stirring technique and to the anechoic scenario using numerical simulations.\",\"PeriodicalId\":438881,\"journal\":{\"name\":\"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/URSIGASS49373.2020.9232246\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 XXXIIIrd General Assembly and Scientific Symposium of the International Union of Radio Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/URSIGASS49373.2020.9232246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Shielding Effectiveness Measurement in a Multiple Monopole Source Stirred Reverberation Chamber
This paper reports the measurement of the shielding effectiveness of a metallic enclosure. The experimental environment is a reverberation chamber where the multiple monopole source stirring technique is implemented. The results are compared to the measurements in the same environment, by using a traditional mechanical stirring technique and to the anechoic scenario using numerical simulations.