Chen-Hao P. Lin, Wiete Fehner, I. Orukari, L. K. Frisk, Alvin Agato, M. Verma, Anthony O’Sullivan, Calamity Svoboda, S. Chetia, A. Eggebrecht, T. Durduran, J. Culver, J. Trobaugh
{"title":"基于纤维的散斑对比光学断层成像用于人体神经成像:高密度与稀疏阵列的模拟和体内人体测量","authors":"Chen-Hao P. Lin, Wiete Fehner, I. Orukari, L. K. Frisk, Alvin Agato, M. Verma, Anthony O’Sullivan, Calamity Svoboda, S. Chetia, A. Eggebrecht, T. Durduran, J. Culver, J. Trobaugh","doi":"10.1364/brain.2023.bth2b.2","DOIUrl":null,"url":null,"abstract":"We simulated speckle contrast optical tomography performance based on an anatomical head model comparing sparse and high-density arrays. We also demonstrated measurements of pulsatile flow on a human head using a multi-mode fiber-based speckle system.","PeriodicalId":111173,"journal":{"name":"Biophotonics Congress: Optics in the Life Sciences 2023 (OMA, NTM, BODA, OMP, BRAIN)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fiber-Based Speckle Contrast Optical Tomography for Neuroimaging in Humans: Simulation of High-Density vs. Sparse Arrays and In Vivo Human Measurements\",\"authors\":\"Chen-Hao P. Lin, Wiete Fehner, I. Orukari, L. K. Frisk, Alvin Agato, M. Verma, Anthony O’Sullivan, Calamity Svoboda, S. Chetia, A. Eggebrecht, T. Durduran, J. Culver, J. Trobaugh\",\"doi\":\"10.1364/brain.2023.bth2b.2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We simulated speckle contrast optical tomography performance based on an anatomical head model comparing sparse and high-density arrays. We also demonstrated measurements of pulsatile flow on a human head using a multi-mode fiber-based speckle system.\",\"PeriodicalId\":111173,\"journal\":{\"name\":\"Biophotonics Congress: Optics in the Life Sciences 2023 (OMA, NTM, BODA, OMP, BRAIN)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biophotonics Congress: Optics in the Life Sciences 2023 (OMA, NTM, BODA, OMP, BRAIN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1364/brain.2023.bth2b.2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophotonics Congress: Optics in the Life Sciences 2023 (OMA, NTM, BODA, OMP, BRAIN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/brain.2023.bth2b.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fiber-Based Speckle Contrast Optical Tomography for Neuroimaging in Humans: Simulation of High-Density vs. Sparse Arrays and In Vivo Human Measurements
We simulated speckle contrast optical tomography performance based on an anatomical head model comparing sparse and high-density arrays. We also demonstrated measurements of pulsatile flow on a human head using a multi-mode fiber-based speckle system.