G. Annaert, A. Barel, R. Luypaert, M. Osteaux, J. Renneboog
{"title":"用于并发/sup 1/H和/sup 31/P核磁共振的低损耗双调谐谐振器","authors":"G. Annaert, A. Barel, R. Luypaert, M. Osteaux, J. Renneboog","doi":"10.1109/IMTC.1989.36849","DOIUrl":null,"url":null,"abstract":"A novel method for double tuning a single nuclear magnetic resonance (NMR) probe, providing two resonances to a single output, simultaneously is described. Both frequencies provide a high sensitivity and are easily tuned with special noninteracting frequency-decoupling circuits. The /sup 1/H (proton) imaging mode of the double-tuned surface coil is actively decoupled from the whole-body, circularly polarized transmit resonator by activating a pin diode circuit. Results for a phantom containing both water and phosphorus acid are shown.<<ETX>>","PeriodicalId":298343,"journal":{"name":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A low-lossy double tuned resonator for concurrent /sup 1/H and /sup 31/P nuclear magnetic resonance\",\"authors\":\"G. Annaert, A. Barel, R. Luypaert, M. Osteaux, J. Renneboog\",\"doi\":\"10.1109/IMTC.1989.36849\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel method for double tuning a single nuclear magnetic resonance (NMR) probe, providing two resonances to a single output, simultaneously is described. Both frequencies provide a high sensitivity and are easily tuned with special noninteracting frequency-decoupling circuits. The /sup 1/H (proton) imaging mode of the double-tuned surface coil is actively decoupled from the whole-body, circularly polarized transmit resonator by activating a pin diode circuit. Results for a phantom containing both water and phosphorus acid are shown.<<ETX>>\",\"PeriodicalId\":298343,\"journal\":{\"name\":\"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.1989.36849\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1989.36849","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A low-lossy double tuned resonator for concurrent /sup 1/H and /sup 31/P nuclear magnetic resonance
A novel method for double tuning a single nuclear magnetic resonance (NMR) probe, providing two resonances to a single output, simultaneously is described. Both frequencies provide a high sensitivity and are easily tuned with special noninteracting frequency-decoupling circuits. The /sup 1/H (proton) imaging mode of the double-tuned surface coil is actively decoupled from the whole-body, circularly polarized transmit resonator by activating a pin diode circuit. Results for a phantom containing both water and phosphorus acid are shown.<>