{"title":"基于无损磁阻传感器的三相地下电力电缆电压通电状态识别","authors":"Ke Zhu, C. Sum, W. Lee, P. Pong","doi":"10.1109/ISNE.2016.7543343","DOIUrl":null,"url":null,"abstract":"Identification of voltage-energized cables can potentially prevent deadly consequences such as electrocution and explosion. We find that the voltage-energized status can be identified by measuring the distribution pattern of magnetic flux density around the cable surface. The weak magnetic fields emitted from the charging current of the voltage-energized cable are measured by sensitive magnetoresistive sensors in high spatial resolution. The feasibility of this non-destructive platform was verified on a 22 kV three-phase underground power cable. The platform can improve situational awareness of serviceman dramatically.","PeriodicalId":127324,"journal":{"name":"2016 5th International Symposium on Next-Generation Electronics (ISNE)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Voltage-energized status identification of three-phase underground power cables via non-destructive magnetoresistive sensor\",\"authors\":\"Ke Zhu, C. Sum, W. Lee, P. Pong\",\"doi\":\"10.1109/ISNE.2016.7543343\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Identification of voltage-energized cables can potentially prevent deadly consequences such as electrocution and explosion. We find that the voltage-energized status can be identified by measuring the distribution pattern of magnetic flux density around the cable surface. The weak magnetic fields emitted from the charging current of the voltage-energized cable are measured by sensitive magnetoresistive sensors in high spatial resolution. The feasibility of this non-destructive platform was verified on a 22 kV three-phase underground power cable. The platform can improve situational awareness of serviceman dramatically.\",\"PeriodicalId\":127324,\"journal\":{\"name\":\"2016 5th International Symposium on Next-Generation Electronics (ISNE)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 5th International Symposium on Next-Generation Electronics (ISNE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISNE.2016.7543343\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 5th International Symposium on Next-Generation Electronics (ISNE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNE.2016.7543343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage-energized status identification of three-phase underground power cables via non-destructive magnetoresistive sensor
Identification of voltage-energized cables can potentially prevent deadly consequences such as electrocution and explosion. We find that the voltage-energized status can be identified by measuring the distribution pattern of magnetic flux density around the cable surface. The weak magnetic fields emitted from the charging current of the voltage-energized cable are measured by sensitive magnetoresistive sensors in high spatial resolution. The feasibility of this non-destructive platform was verified on a 22 kV three-phase underground power cable. The platform can improve situational awareness of serviceman dramatically.