E. Huber
{"title":"高阶系统的自适应控制技术","authors":"E. Huber","doi":"10.1109/TAC.1962.1105453","DOIUrl":null,"url":null,"abstract":"A technique which is a modification of the model-reference method of adaptive control is developed to handle high-order systems. The transfer function of the model is the inverse of the desired transfer function of the closed-loop system insofar as it is practically realizable. Proper operation is obtained by adjusting the system until the poles of the closed-loop system are canceled by the zeros of the model. Special filters are designed to aid in the detection of this cancellation. They have a narrow pulse for an impulse response and the dispersion of this pulse is used as the measure of error when an impulse is applied to the system. The criterion used for the design of the filter is that its impulse response should have a minimum second moment about the time of the maximum. The technique is applied to a fourth-order pitch-rate control system and the results of the computer simulation are given.","PeriodicalId":226447,"journal":{"name":"Ire Transactions on Automatic Control","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A technique for the adaptive control of high-order systems\",\"authors\":\"E. Huber\",\"doi\":\"10.1109/TAC.1962.1105453\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A technique which is a modification of the model-reference method of adaptive control is developed to handle high-order systems. The transfer function of the model is the inverse of the desired transfer function of the closed-loop system insofar as it is practically realizable. Proper operation is obtained by adjusting the system until the poles of the closed-loop system are canceled by the zeros of the model. Special filters are designed to aid in the detection of this cancellation. They have a narrow pulse for an impulse response and the dispersion of this pulse is used as the measure of error when an impulse is applied to the system. The criterion used for the design of the filter is that its impulse response should have a minimum second moment about the time of the maximum. The technique is applied to a fourth-order pitch-rate control system and the results of the computer simulation are given.\",\"PeriodicalId\":226447,\"journal\":{\"name\":\"Ire Transactions on Automatic Control\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1962-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ire Transactions on Automatic Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAC.1962.1105453\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ire Transactions on Automatic Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAC.1962.1105453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种改进模型参考自适应控制方法的高阶系统控制方法。在实际可行的范围内,模型的传递函数是闭环系统期望传递函数的逆。通过调整系统,直到闭环系统的极点被模型的零点抵消,从而获得正常的运行。特殊的过滤器被设计来帮助检测这种抵消。它们有一个用于脉冲响应的窄脉冲,当脉冲应用于系统时,这个脉冲的色散被用作误差的度量。用于设计滤波器的准则是,它的脉冲响应应该有一个最小的第二矩,大约是最大的时间。将该方法应用于一个四阶螺距速率控制系统,并给出了计算机仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A technique for the adaptive control of high-order systems
A technique which is a modification of the model-reference method of adaptive control is developed to handle high-order systems. The transfer function of the model is the inverse of the desired transfer function of the closed-loop system insofar as it is practically realizable. Proper operation is obtained by adjusting the system until the poles of the closed-loop system are canceled by the zeros of the model. Special filters are designed to aid in the detection of this cancellation. They have a narrow pulse for an impulse response and the dispersion of this pulse is used as the measure of error when an impulse is applied to the system. The criterion used for the design of the filter is that its impulse response should have a minimum second moment about the time of the maximum. The technique is applied to a fourth-order pitch-rate control system and the results of the computer simulation are given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信