磨损尖尖的传热及气膜冷却效果研究

Mingliang Ye, Xin Yan
{"title":"磨损尖尖的传热及气膜冷却效果研究","authors":"Mingliang Ye, Xin Yan","doi":"10.1115/GT2020-14835","DOIUrl":null,"url":null,"abstract":"\n Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl = 25%Cax, 50%Cax and 75%Cax) and five wear-depths (wd = 0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3–6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7–29.1% while on squealer rim it is decreased by 3.1–26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.","PeriodicalId":147616,"journal":{"name":"Volume 7B: Heat Transfer","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Investigations of Heat Transfer and Film Cooling Effect on a Worn Squealer Tip\",\"authors\":\"Mingliang Ye, Xin Yan\",\"doi\":\"10.1115/GT2020-14835\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl = 25%Cax, 50%Cax and 75%Cax) and five wear-depths (wd = 0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3–6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7–29.1% while on squealer rim it is decreased by 3.1–26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.\",\"PeriodicalId\":147616,\"journal\":{\"name\":\"Volume 7B: Heat Transfer\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 7B: Heat Transfer\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/GT2020-14835\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 7B: Heat Transfer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/GT2020-14835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

现代燃气轮机转子叶尖由于旋转部件和静止部件之间的相对运动和膨胀而产生磨损损伤。叶尖磨损对动叶的气动性能、传热性能和冷却性能都有重大影响,从而威胁到整个燃气轮机系统的经济性和安全性。基于简单的线性磨损模型,对三种磨损起始位置(sl = 25%Cax、50%Cax和75%Cax)和五种磨损深度(wd = 0.82%、1.64%、2.46%、3.28%和4.10%)下的磨损尖部气动性能、传热性能和气膜冷却性能进行了数值研究。首先,在现有实验数据的基础上,对数值方法和网格独立性进行了详细的研究。然后,计算了磨损尖部区域的三维流场、总压损失分布、换热系数和气膜冷却效率,并与原设计情况进行了比较。结果表明:随着磨损深度的增加和磨损起始位置向前缘移动,空腔涡的规模和强度增大,导致靠近前缘的空腔底板高换热面积扩大;磨损使腔体流出的冷却液增多,降低了腔体底部的平均面积气膜冷却效率,但提高了压力侧边缘的气膜冷却效率。磨损深度的增加使更多的流量通过叶尖间隙泄漏,从而增加了泄漏涡的规模和强度,进一步增加了叶尖间隙内的总压损失。与原设计工况相比,当磨损深度从0.82%增加到4.10%时,叶栅质量平均总压损失增加0.3 ~ 6.7%,空腔底板面积平均换热系数增加1.7 ~ 29.1%,尖叫边缘面积平均换热系数降低3.1 ~ 26.3%,空腔底板面积平均气膜冷却效率降低0.035,尖叫边缘面积平均气膜冷却效率降低0.064。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigations of Heat Transfer and Film Cooling Effect on a Worn Squealer Tip
Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl = 25%Cax, 50%Cax and 75%Cax) and five wear-depths (wd = 0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3–6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7–29.1% while on squealer rim it is decreased by 3.1–26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信