{"title":"继电器浪涌负荷试验设计及结果分析","authors":"Huimin Liang, Haidan Yu, Guangcheng Ma, Z. Cai, Yujie Tang, Chunqing Zhao","doi":"10.1109/HOLM.2015.7355082","DOIUrl":null,"url":null,"abstract":"Due to the transient overvoltage or overcurrent when relay's contacts switch different loads, the relay's contacts are damaged by transient arc erosion of electrical-over-stress, which influences the reliability of relay seriously. Firstly, according to the life test requirements of one type of electromagnetic relay with permanent magnets, the load circuit and the testing program are designed, which has characteristic of adjustable surge current time. Secondly, the contacts' breaking arc and closing bounce under 2A resistive load, 5A resistive load and surge load are analyzed. The influence of surge load on relay's electrical life is studied with increasing of test cycles. Finally, based on the testing data, the optimal design of relay has been modified and the results have been analyzed, which is helpful for improving the life of the relay.","PeriodicalId":448541,"journal":{"name":"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Surge load experiment design and results analysis of relay\",\"authors\":\"Huimin Liang, Haidan Yu, Guangcheng Ma, Z. Cai, Yujie Tang, Chunqing Zhao\",\"doi\":\"10.1109/HOLM.2015.7355082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to the transient overvoltage or overcurrent when relay's contacts switch different loads, the relay's contacts are damaged by transient arc erosion of electrical-over-stress, which influences the reliability of relay seriously. Firstly, according to the life test requirements of one type of electromagnetic relay with permanent magnets, the load circuit and the testing program are designed, which has characteristic of adjustable surge current time. Secondly, the contacts' breaking arc and closing bounce under 2A resistive load, 5A resistive load and surge load are analyzed. The influence of surge load on relay's electrical life is studied with increasing of test cycles. Finally, based on the testing data, the optimal design of relay has been modified and the results have been analyzed, which is helpful for improving the life of the relay.\",\"PeriodicalId\":448541,\"journal\":{\"name\":\"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2015.7355082\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 61st Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2015.7355082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

由于继电器触点在切换不同负载时产生的瞬态过电压或过电流,导致继电器触点受到电过应力瞬态电弧侵蚀而损坏,严重影响了继电器的可靠性。首先,根据某型永磁体电磁继电器的寿命试验要求,设计了浪涌电流时间可调的负载电路和试验程序。其次,分析了在2A电阻性负载、5A电阻性负载和浪涌负载下触点的断弧和合闸弹跳。随着试验次数的增加,研究了浪涌负荷对继电器电气寿命的影响。最后,根据试验数据对继电器的优化设计进行了修改,并对结果进行了分析,有助于提高继电器的使用寿命。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Surge load experiment design and results analysis of relay
Due to the transient overvoltage or overcurrent when relay's contacts switch different loads, the relay's contacts are damaged by transient arc erosion of electrical-over-stress, which influences the reliability of relay seriously. Firstly, according to the life test requirements of one type of electromagnetic relay with permanent magnets, the load circuit and the testing program are designed, which has characteristic of adjustable surge current time. Secondly, the contacts' breaking arc and closing bounce under 2A resistive load, 5A resistive load and surge load are analyzed. The influence of surge load on relay's electrical life is studied with increasing of test cycles. Finally, based on the testing data, the optimal design of relay has been modified and the results have been analyzed, which is helpful for improving the life of the relay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信