R. Soltani, Pascalina Gaillardetz, I. Chichkin, Bruce Ledger
{"title":"某大型水轮发电机局部放电活动及绝缘寿命研究","authors":"R. Soltani, Pascalina Gaillardetz, I. Chichkin, Bruce Ledger","doi":"10.1109/EIC43217.2019.9046557","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) is a well-known indicator of an aging insulation system, so trending the PD activity is suggested as a tool to prevent insulation failures by targeted interventions. This paper presents a case study in which on-line PD measurements showed a significant increase over several years and triggered an investigation and repair plan. Off-line site tests confirmed the concerns and helped in locating and replacing the most vulnerable bars. Laboratory tests on the service-aged bars also provided valuable information about the root cause and insulation condition of the winding.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Investigation of Partial Discharge Activity and Insulation Life of a Large Hydro Generator\",\"authors\":\"R. Soltani, Pascalina Gaillardetz, I. Chichkin, Bruce Ledger\",\"doi\":\"10.1109/EIC43217.2019.9046557\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge (PD) is a well-known indicator of an aging insulation system, so trending the PD activity is suggested as a tool to prevent insulation failures by targeted interventions. This paper presents a case study in which on-line PD measurements showed a significant increase over several years and triggered an investigation and repair plan. Off-line site tests confirmed the concerns and helped in locating and replacing the most vulnerable bars. Laboratory tests on the service-aged bars also provided valuable information about the root cause and insulation condition of the winding.\",\"PeriodicalId\":340602,\"journal\":{\"name\":\"2019 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC43217.2019.9046557\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of Partial Discharge Activity and Insulation Life of a Large Hydro Generator
Partial discharge (PD) is a well-known indicator of an aging insulation system, so trending the PD activity is suggested as a tool to prevent insulation failures by targeted interventions. This paper presents a case study in which on-line PD measurements showed a significant increase over several years and triggered an investigation and repair plan. Off-line site tests confirmed the concerns and helped in locating and replacing the most vulnerable bars. Laboratory tests on the service-aged bars also provided valuable information about the root cause and insulation condition of the winding.