{"title":"基于/spl α -射线响应特性的PBI/sub - 2晶体辐射探测器表征","authors":"T. Shoji, K. Ohba, T. Suehiro, Y. Hiratate","doi":"10.1109/NSSMIC.1993.701655","DOIUrl":null,"url":null,"abstract":"An improved method is proposed for the production of single crystals of lead iodide (PbIb. This method is basically a four-pass Bridgman method. Bulk-type nuclear radiation detectors have been fabricated by use of crystals grown by the present method. The characteristics of the detectors, particularly the response for a-particles with an energy of 5.48 MeV has been measured and compared with that of other detectors fabricated with materials grown by the ordinary Bridgman method. A clear peak has been successfully observed in the pulse-height spectrum. On the other hand no peak has been observed with the detector by the material grown by the ordinary Bridgman method. From the measurements of peak position versus applied bias voltage the average energy for the production of electron-hole pairs and the pz product of hole are estimated as about 30 eV and lo-' cm2/V, respectively.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"145 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterization Of Radiation Detector Using The PBI/sub 2/crystal By Response Properties Of /spl alpha/-rays\",\"authors\":\"T. Shoji, K. Ohba, T. Suehiro, Y. Hiratate\",\"doi\":\"10.1109/NSSMIC.1993.701655\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An improved method is proposed for the production of single crystals of lead iodide (PbIb. This method is basically a four-pass Bridgman method. Bulk-type nuclear radiation detectors have been fabricated by use of crystals grown by the present method. The characteristics of the detectors, particularly the response for a-particles with an energy of 5.48 MeV has been measured and compared with that of other detectors fabricated with materials grown by the ordinary Bridgman method. A clear peak has been successfully observed in the pulse-height spectrum. On the other hand no peak has been observed with the detector by the material grown by the ordinary Bridgman method. From the measurements of peak position versus applied bias voltage the average energy for the production of electron-hole pairs and the pz product of hole are estimated as about 30 eV and lo-' cm2/V, respectively.\",\"PeriodicalId\":287813,\"journal\":{\"name\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"volume\":\"145 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1993.701655\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.701655","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Characterization Of Radiation Detector Using The PBI/sub 2/crystal By Response Properties Of /spl alpha/-rays
An improved method is proposed for the production of single crystals of lead iodide (PbIb. This method is basically a four-pass Bridgman method. Bulk-type nuclear radiation detectors have been fabricated by use of crystals grown by the present method. The characteristics of the detectors, particularly the response for a-particles with an energy of 5.48 MeV has been measured and compared with that of other detectors fabricated with materials grown by the ordinary Bridgman method. A clear peak has been successfully observed in the pulse-height spectrum. On the other hand no peak has been observed with the detector by the material grown by the ordinary Bridgman method. From the measurements of peak position versus applied bias voltage the average energy for the production of electron-hole pairs and the pz product of hole are estimated as about 30 eV and lo-' cm2/V, respectively.