{"title":"PWM控制采用修改三角信号","authors":"Yaow-Ming Chen, Yuan-Ming Cheng","doi":"10.1109/IECON.1999.822216","DOIUrl":null,"url":null,"abstract":"The proposed analog-based modified PWM control scheme for the DC-AC inverter can eliminate the low order harmonic components caused by the nonconstant DC voltage source. A simple high-power factor full-bridge rectifier with the valley-fill filter is selected to realize the nonconstant DC voltage source. The development of a modified triangular signal for the PWM control is introduced in this paper. The performance of the proposed modified PWM control scheme is verified by using computer simulation and experimental results.","PeriodicalId":378710,"journal":{"name":"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"PWM control using a modified triangular signal\",\"authors\":\"Yaow-Ming Chen, Yuan-Ming Cheng\",\"doi\":\"10.1109/IECON.1999.822216\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The proposed analog-based modified PWM control scheme for the DC-AC inverter can eliminate the low order harmonic components caused by the nonconstant DC voltage source. A simple high-power factor full-bridge rectifier with the valley-fill filter is selected to realize the nonconstant DC voltage source. The development of a modified triangular signal for the PWM control is introduced in this paper. The performance of the proposed modified PWM control scheme is verified by using computer simulation and experimental results.\",\"PeriodicalId\":378710,\"journal\":{\"name\":\"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1999.822216\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON'99. Conference Proceedings. 25th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.99CH37029)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1999.822216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The proposed analog-based modified PWM control scheme for the DC-AC inverter can eliminate the low order harmonic components caused by the nonconstant DC voltage source. A simple high-power factor full-bridge rectifier with the valley-fill filter is selected to realize the nonconstant DC voltage source. The development of a modified triangular signal for the PWM control is introduced in this paper. The performance of the proposed modified PWM control scheme is verified by using computer simulation and experimental results.