基于模拟方法的大型电网环衰观测区间模态灵敏度研究

W. Trinh, Sanjana Kunkolienkar, Yijing Liu, T. Overbye
{"title":"基于模拟方法的大型电网环衰观测区间模态灵敏度研究","authors":"W. Trinh, Sanjana Kunkolienkar, Yijing Liu, T. Overbye","doi":"10.1109/PECI54197.2022.9744012","DOIUrl":null,"url":null,"abstract":"This paper presents results on the sensitivity of the inter-area electromechanical modes obtained by ring-down, measurement-based modal analysis for large-scale electric grids. The paper utilizes the Iterative Matrix Pencil Method (IMP) to determine the most significant electro-mechanical modes and their associated mode shapes after the system has been perturbed by generator or load outage contingencies. The paper shows that the resultant values can be dependent on both the applied contingency and the set of signals used in the IMP with this sensitivity due at least in part to the system nonlinearities. The techniques are demonstrated using three synthetic grids ranging in size between 2000 and 70,000 buses. Visualization methods are used to show the mode shapes and compare and contrast how modes manifest themselves on the grid.","PeriodicalId":245119,"journal":{"name":"2022 IEEE Power and Energy Conference at Illinois (PECI)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"On the Sensitivity of Ring-Down Observed Inter-Area Modes in Large-Scale Electric Grids Using a Simulation Approach\",\"authors\":\"W. Trinh, Sanjana Kunkolienkar, Yijing Liu, T. Overbye\",\"doi\":\"10.1109/PECI54197.2022.9744012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents results on the sensitivity of the inter-area electromechanical modes obtained by ring-down, measurement-based modal analysis for large-scale electric grids. The paper utilizes the Iterative Matrix Pencil Method (IMP) to determine the most significant electro-mechanical modes and their associated mode shapes after the system has been perturbed by generator or load outage contingencies. The paper shows that the resultant values can be dependent on both the applied contingency and the set of signals used in the IMP with this sensitivity due at least in part to the system nonlinearities. The techniques are demonstrated using three synthetic grids ranging in size between 2000 and 70,000 buses. Visualization methods are used to show the mode shapes and compare and contrast how modes manifest themselves on the grid.\",\"PeriodicalId\":245119,\"journal\":{\"name\":\"2022 IEEE Power and Energy Conference at Illinois (PECI)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Power and Energy Conference at Illinois (PECI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECI54197.2022.9744012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI54197.2022.9744012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了大型电网区域间机电模态的灵敏度分析结果。本文利用迭代矩阵铅笔法(IMP)来确定系统受到发电机或负载中断事故扰动后最重要的机电模态及其相关模态振型。本文表明,结果值可以依赖于应用的偶然性和在IMP中使用的信号集,这种灵敏度至少部分是由于系统的非线性。这些技术是用三个合成网格来演示的,网格的大小在2000到7万辆公交车之间。可视化方法用于显示模态振型,并比较和对比模态在网格上的表现方式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the Sensitivity of Ring-Down Observed Inter-Area Modes in Large-Scale Electric Grids Using a Simulation Approach
This paper presents results on the sensitivity of the inter-area electromechanical modes obtained by ring-down, measurement-based modal analysis for large-scale electric grids. The paper utilizes the Iterative Matrix Pencil Method (IMP) to determine the most significant electro-mechanical modes and their associated mode shapes after the system has been perturbed by generator or load outage contingencies. The paper shows that the resultant values can be dependent on both the applied contingency and the set of signals used in the IMP with this sensitivity due at least in part to the system nonlinearities. The techniques are demonstrated using three synthetic grids ranging in size between 2000 and 70,000 buses. Visualization methods are used to show the mode shapes and compare and contrast how modes manifest themselves on the grid.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信