行人路照度计算研究个案

Alexandru Viorel Rusu, D. Lucache, G. Livint
{"title":"行人路照度计算研究个案","authors":"Alexandru Viorel Rusu, D. Lucache, G. Livint","doi":"10.1109/SIELMEN.2019.8905919","DOIUrl":null,"url":null,"abstract":"This paper presents a technical case study regarding Footpaths lighting class parameters and the way of selecting them in street lighting design around the world. Because some countries have very similar parameters the study was made only for Romania, England, U.S.A. and Denmark. The study consists in DIALux calculation for each lighting class and power consumption needed for each standard value to be acquired. The conclusion of the paper is that the lighting classes with the highest consumption and the most restrictive standard when selecting the lighting class for each roads is in Romania which actually gives the maximum W/km of road almost all the time.","PeriodicalId":129030,"journal":{"name":"2019 International Conference on Electromechanical and Energy Systems (SIELMEN)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Study Case for Illuminance Calculation for Footpaths\",\"authors\":\"Alexandru Viorel Rusu, D. Lucache, G. Livint\",\"doi\":\"10.1109/SIELMEN.2019.8905919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a technical case study regarding Footpaths lighting class parameters and the way of selecting them in street lighting design around the world. Because some countries have very similar parameters the study was made only for Romania, England, U.S.A. and Denmark. The study consists in DIALux calculation for each lighting class and power consumption needed for each standard value to be acquired. The conclusion of the paper is that the lighting classes with the highest consumption and the most restrictive standard when selecting the lighting class for each roads is in Romania which actually gives the maximum W/km of road almost all the time.\",\"PeriodicalId\":129030,\"journal\":{\"name\":\"2019 International Conference on Electromechanical and Energy Systems (SIELMEN)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Electromechanical and Energy Systems (SIELMEN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIELMEN.2019.8905919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electromechanical and Energy Systems (SIELMEN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIELMEN.2019.8905919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了世界各国道路照明设计中行人路照明等级参数的技术案例及选择方法。由于一些国家有非常相似的参数,本研究仅针对罗马尼亚、英国、美国和丹麦进行。该研究包括对每个照明类别的DIALux计算和获得每个标准值所需的功耗。本文的结论是,在选择每条道路的照明等级时,消耗最高,限制标准最严格的照明等级是罗马尼亚,实际上几乎所有时候都给出了道路的最大W/km。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study Case for Illuminance Calculation for Footpaths
This paper presents a technical case study regarding Footpaths lighting class parameters and the way of selecting them in street lighting design around the world. Because some countries have very similar parameters the study was made only for Romania, England, U.S.A. and Denmark. The study consists in DIALux calculation for each lighting class and power consumption needed for each standard value to be acquired. The conclusion of the paper is that the lighting classes with the highest consumption and the most restrictive standard when selecting the lighting class for each roads is in Romania which actually gives the maximum W/km of road almost all the time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信