微波和发光二极管消毒对聚甲基丙烯酸甲酯和聚酰胺义齿基托树脂尺寸稳定性的影响

H. Rehman
{"title":"微波和发光二极管消毒对聚甲基丙烯酸甲酯和聚酰胺义齿基托树脂尺寸稳定性的影响","authors":"H. Rehman","doi":"10.57234/1472","DOIUrl":null,"url":null,"abstract":"Objective: To compare the effects of microwave and light emitting diode disinfection on the dimensional stability of two denture base materials; polymethyl methacrylate and polyamide. Study Design: In-vitro study Place and Duration of Study: Peshawar Dental College and Material Research Laboratories, University of Peshawar from 10 June 2021 to 8 December 2021. Materials and Methods: Fifteen specimens each for polymethylmethacrylate and polyamide were divided into three groups, control, microwave & light emitting diode. The specimens for microwave group were irradiated at 1000W for 3 minutes, thrice a week. The specimens for light emitting diode group were disinfected in a device for 30 minutes, thrice a week. The control group specimens were placed in distilled water for 4 weeks. Dimensions were measured before disinfection, and four weeks after the assigned disinfection. The mean and the standard deviation of the differences between three groups were statistically analyzed using one-way ANOVA and after obtaining significant values, through post hoc Tukey HSD. Results: For polymethylmethacrylate highest dimensional difference (-9.02mm) was noted for microwave disinfected group while the control group showed the lowest value (-6.99mm). For polyamide, the highest dimensional changes were recorded for light emitting diode group (8.66mm) and the lowest (-7mm) for the control group. Statistical analysis showed that the differences were significant for both polymethylmethacrylate and polyamide when compared with the control (p<0.05) but insignificant when microwave disinfected group was compared with light emitting diode group (p>0.05) Conclusion: No significant difference in dimensional stability of both the denture base resins was observed after disinfection with microwave and light emitting diode.","PeriodicalId":441218,"journal":{"name":"Journal of Islamic International Medical College","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of Microwave and Light Emitting Diode as Disinfection Methods on the Dimensional Stability of Polymethyl Methacrylate and Polyamide Denture Base Resin\",\"authors\":\"H. Rehman\",\"doi\":\"10.57234/1472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To compare the effects of microwave and light emitting diode disinfection on the dimensional stability of two denture base materials; polymethyl methacrylate and polyamide. Study Design: In-vitro study Place and Duration of Study: Peshawar Dental College and Material Research Laboratories, University of Peshawar from 10 June 2021 to 8 December 2021. Materials and Methods: Fifteen specimens each for polymethylmethacrylate and polyamide were divided into three groups, control, microwave & light emitting diode. The specimens for microwave group were irradiated at 1000W for 3 minutes, thrice a week. The specimens for light emitting diode group were disinfected in a device for 30 minutes, thrice a week. The control group specimens were placed in distilled water for 4 weeks. Dimensions were measured before disinfection, and four weeks after the assigned disinfection. The mean and the standard deviation of the differences between three groups were statistically analyzed using one-way ANOVA and after obtaining significant values, through post hoc Tukey HSD. Results: For polymethylmethacrylate highest dimensional difference (-9.02mm) was noted for microwave disinfected group while the control group showed the lowest value (-6.99mm). For polyamide, the highest dimensional changes were recorded for light emitting diode group (8.66mm) and the lowest (-7mm) for the control group. Statistical analysis showed that the differences were significant for both polymethylmethacrylate and polyamide when compared with the control (p<0.05) but insignificant when microwave disinfected group was compared with light emitting diode group (p>0.05) Conclusion: No significant difference in dimensional stability of both the denture base resins was observed after disinfection with microwave and light emitting diode.\",\"PeriodicalId\":441218,\"journal\":{\"name\":\"Journal of Islamic International Medical College\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Islamic International Medical College\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.57234/1472\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Islamic International Medical College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.57234/1472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较微波消毒与发光二极管消毒对两种义齿基托材料尺寸稳定性的影响;聚甲基丙烯酸甲酯和聚酰胺。研究设计:体外研究地点和研究时间:白沙瓦大学白沙瓦牙科学院和材料研究实验室,2021年6月10日至2021年12月8日。材料与方法:聚甲基丙烯酸甲酯和聚酰胺各15个样品分为对照组、微波组和发光二极管组。微波组以1000W辐照3分钟,每周3次。发光二极管组在消毒装置中消毒30分钟,每周3次。对照组标本置于蒸馏水中4周。在消毒前和指定消毒后四周测量尺寸。三组间差异的均值和标准差采用单因素方差分析(one-way ANOVA)进行统计学分析,获得显著值后采用事后Tukey HSD进行统计学分析。结果:微波消毒组聚甲基丙烯酸甲酯的尺寸差异最大(-9.02mm),对照组的尺寸差异最小(-6.99mm)。对于聚酰胺,发光二极管组的尺寸变化最大(8.66mm),而对照组的尺寸变化最小(-7mm)。经统计学分析,聚甲基丙烯酸甲酯和聚酰胺与对照组比较,差异均有统计学意义(p0.05)。结论:微波消毒和发光二极管消毒后,两种义齿基托树脂的尺寸稳定性无显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of Microwave and Light Emitting Diode as Disinfection Methods on the Dimensional Stability of Polymethyl Methacrylate and Polyamide Denture Base Resin
Objective: To compare the effects of microwave and light emitting diode disinfection on the dimensional stability of two denture base materials; polymethyl methacrylate and polyamide. Study Design: In-vitro study Place and Duration of Study: Peshawar Dental College and Material Research Laboratories, University of Peshawar from 10 June 2021 to 8 December 2021. Materials and Methods: Fifteen specimens each for polymethylmethacrylate and polyamide were divided into three groups, control, microwave & light emitting diode. The specimens for microwave group were irradiated at 1000W for 3 minutes, thrice a week. The specimens for light emitting diode group were disinfected in a device for 30 minutes, thrice a week. The control group specimens were placed in distilled water for 4 weeks. Dimensions were measured before disinfection, and four weeks after the assigned disinfection. The mean and the standard deviation of the differences between three groups were statistically analyzed using one-way ANOVA and after obtaining significant values, through post hoc Tukey HSD. Results: For polymethylmethacrylate highest dimensional difference (-9.02mm) was noted for microwave disinfected group while the control group showed the lowest value (-6.99mm). For polyamide, the highest dimensional changes were recorded for light emitting diode group (8.66mm) and the lowest (-7mm) for the control group. Statistical analysis showed that the differences were significant for both polymethylmethacrylate and polyamide when compared with the control (p<0.05) but insignificant when microwave disinfected group was compared with light emitting diode group (p>0.05) Conclusion: No significant difference in dimensional stability of both the denture base resins was observed after disinfection with microwave and light emitting diode.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信