地球空气热交换器的CFD计算研究:参数分析

Shiv Lal
{"title":"地球空气热交换器的CFD计算研究:参数分析","authors":"Shiv Lal","doi":"10.54060/jmce.v3i1.29","DOIUrl":null,"url":null,"abstract":"Parametric studies of earth air tunnel heat exchanger (EATHE) using FLUENT 6.3 Computational fluid dynamics (CFD) software have been carried out in this paper. From the parametric analysis it is found that economic analysis of the system is required for the optimization of length, diameter, and depth of buried pipe. For a long earth air tunnel more than 60 m, soil thermal conductivity doesn’t give any significant effect. The higher mass flow rate also increases the overall energy conservation potential of the system, but it reduces thermal comfort. So, the mass flow rate also takes to optimize according to the requirement. This study is beneficial to the design and energy researchers of this field.","PeriodicalId":142002,"journal":{"name":"Journal of Mechanical and Construction Engineering (JMCE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Computational Studies of Earth Air Heat Exchanger using CFD: Parametric Analysis\",\"authors\":\"Shiv Lal\",\"doi\":\"10.54060/jmce.v3i1.29\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Parametric studies of earth air tunnel heat exchanger (EATHE) using FLUENT 6.3 Computational fluid dynamics (CFD) software have been carried out in this paper. From the parametric analysis it is found that economic analysis of the system is required for the optimization of length, diameter, and depth of buried pipe. For a long earth air tunnel more than 60 m, soil thermal conductivity doesn’t give any significant effect. The higher mass flow rate also increases the overall energy conservation potential of the system, but it reduces thermal comfort. So, the mass flow rate also takes to optimize according to the requirement. This study is beneficial to the design and energy researchers of this field.\",\"PeriodicalId\":142002,\"journal\":{\"name\":\"Journal of Mechanical and Construction Engineering (JMCE)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mechanical and Construction Engineering (JMCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54060/jmce.v3i1.29\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechanical and Construction Engineering (JMCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54060/jmce.v3i1.29","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文利用FLUENT 6.3计算流体力学(CFD)软件对土空气隧道式换热器(EATHE)进行了参数化研究。从参数分析中发现,对埋管长度、管径和埋管深度的优化需要对系统进行经济分析。对于大于60 m的长土风洞,土壤导热系数对其影响不显著。较高的质量流量也增加了系统的整体节能潜力,但降低了热舒适性。因此,质量流量也需按要求进行优化。本研究对该领域的设计和能源研究者有一定的借鉴意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computational Studies of Earth Air Heat Exchanger using CFD: Parametric Analysis
Parametric studies of earth air tunnel heat exchanger (EATHE) using FLUENT 6.3 Computational fluid dynamics (CFD) software have been carried out in this paper. From the parametric analysis it is found that economic analysis of the system is required for the optimization of length, diameter, and depth of buried pipe. For a long earth air tunnel more than 60 m, soil thermal conductivity doesn’t give any significant effect. The higher mass flow rate also increases the overall energy conservation potential of the system, but it reduces thermal comfort. So, the mass flow rate also takes to optimize according to the requirement. This study is beneficial to the design and energy researchers of this field.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信