{"title":"泄漏电感对高频变压器谐波的影响","authors":"B. Abdi, Mohammad Hadi Joukar, A. Ranjbar","doi":"10.1109/CPE.2009.5156060","DOIUrl":null,"url":null,"abstract":"Nowadays, switching power supplies are used in almost all electronic devices to regulate the voltage amplitude. The only obstacle on using these devices is the production of high frequency harmonics that violates different standards such as (FCC, VDE, 461). In this paper the sources of various noises in switching power supplies will be introduced. Then, using appropriate model for high frequency transformers, a sample switching power supply will be simulated. In this simulation, the effect of leakage inductance on current and voltage waveforms of the input and output switches, which are the main cause of common mode differential mode noises and radiations, will be discussed and harmonically analyzed. Finally the experimental results will confirm the simulation conclusions.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effect of leakage inductance on high frequency transformer harmonics\",\"authors\":\"B. Abdi, Mohammad Hadi Joukar, A. Ranjbar\",\"doi\":\"10.1109/CPE.2009.5156060\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays, switching power supplies are used in almost all electronic devices to regulate the voltage amplitude. The only obstacle on using these devices is the production of high frequency harmonics that violates different standards such as (FCC, VDE, 461). In this paper the sources of various noises in switching power supplies will be introduced. Then, using appropriate model for high frequency transformers, a sample switching power supply will be simulated. In this simulation, the effect of leakage inductance on current and voltage waveforms of the input and output switches, which are the main cause of common mode differential mode noises and radiations, will be discussed and harmonically analyzed. Finally the experimental results will confirm the simulation conclusions.\",\"PeriodicalId\":272748,\"journal\":{\"name\":\"2009 Compatibility and Power Electronics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Compatibility and Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE.2009.5156060\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of leakage inductance on high frequency transformer harmonics
Nowadays, switching power supplies are used in almost all electronic devices to regulate the voltage amplitude. The only obstacle on using these devices is the production of high frequency harmonics that violates different standards such as (FCC, VDE, 461). In this paper the sources of various noises in switching power supplies will be introduced. Then, using appropriate model for high frequency transformers, a sample switching power supply will be simulated. In this simulation, the effect of leakage inductance on current and voltage waveforms of the input and output switches, which are the main cause of common mode differential mode noises and radiations, will be discussed and harmonically analyzed. Finally the experimental results will confirm the simulation conclusions.