双向DC - DC变换器中漏感的影响

Kunalkumar Bhatt, M. Shah, V. Patel, Vijendra Kharbikar
{"title":"双向DC - DC变换器中漏感的影响","authors":"Kunalkumar Bhatt, M. Shah, V. Patel, Vijendra Kharbikar","doi":"10.1109/NUICONE.2011.6153303","DOIUrl":null,"url":null,"abstract":"This work presents an isolated full-bridge bidirectional DC/DC converter for battery charging/discharging operation. In the proposed scheme, the full-bridge isolated topology is used for the DC-DC conversion. The full bridge scheme is widely used for the high power application. High frequency transformer is used for isolation purpose. This paper deals with the effect of leakage inductance of high frequency transformer in the charging mode as well as discharge mode of operation. Phase shifted topology is used as control scheme. Effect of leakage inductance on output voltage, output current is shown in simulation. Simulation results are obtained using PSIM Software with a 7.75-kW load. Test result is given for effectiveness of the study. Battery rating 310 V, 25 A.","PeriodicalId":206392,"journal":{"name":"2011 Nirma University International Conference on Engineering","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of leakage inductance in bidirectional DC to DC converter\",\"authors\":\"Kunalkumar Bhatt, M. Shah, V. Patel, Vijendra Kharbikar\",\"doi\":\"10.1109/NUICONE.2011.6153303\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work presents an isolated full-bridge bidirectional DC/DC converter for battery charging/discharging operation. In the proposed scheme, the full-bridge isolated topology is used for the DC-DC conversion. The full bridge scheme is widely used for the high power application. High frequency transformer is used for isolation purpose. This paper deals with the effect of leakage inductance of high frequency transformer in the charging mode as well as discharge mode of operation. Phase shifted topology is used as control scheme. Effect of leakage inductance on output voltage, output current is shown in simulation. Simulation results are obtained using PSIM Software with a 7.75-kW load. Test result is given for effectiveness of the study. Battery rating 310 V, 25 A.\",\"PeriodicalId\":206392,\"journal\":{\"name\":\"2011 Nirma University International Conference on Engineering\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Nirma University International Conference on Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NUICONE.2011.6153303\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Nirma University International Conference on Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NUICONE.2011.6153303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种隔离式全桥双向DC/DC变换器,用于电池充放电操作。在该方案中,采用全桥隔离拓扑进行DC-DC转换。全桥方案在大功率应用中得到广泛应用。高频变压器用于隔离。本文研究了高频变压器在充电和放电两种工作方式下漏感的影响。采用相移拓扑作为控制方案。仿真显示了漏感对输出电压、输出电流的影响。采用PSIM软件对7.75 kw负载进行了仿真。实验结果表明了该方法的有效性。电池额定电压310v, 25a。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of leakage inductance in bidirectional DC to DC converter
This work presents an isolated full-bridge bidirectional DC/DC converter for battery charging/discharging operation. In the proposed scheme, the full-bridge isolated topology is used for the DC-DC conversion. The full bridge scheme is widely used for the high power application. High frequency transformer is used for isolation purpose. This paper deals with the effect of leakage inductance of high frequency transformer in the charging mode as well as discharge mode of operation. Phase shifted topology is used as control scheme. Effect of leakage inductance on output voltage, output current is shown in simulation. Simulation results are obtained using PSIM Software with a 7.75-kW load. Test result is given for effectiveness of the study. Battery rating 310 V, 25 A.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信