{"title":"全电船舶及船用非线性干式变压器的设计","authors":"B. Housseini, A. F. Okou, M. Tarbouchi, D. Bouchard, A. Zidan","doi":"10.1109/IECON.2018.8591448","DOIUrl":null,"url":null,"abstract":"This paper presents a design of a high power nonlinear dry-type electric transformer used in All-Electric Ship (AES) and marine applications. Some nonlinear transformer models can be found in the literature. However, in these models, the effects of hysteresis and saturation in the core and windings are modeled using lookup table blocks. A lookup table, by definition, uses an array of data to map input values to output values, approximating a mathematical function. As the data array is static, the model is valid just for one defined transformer. The proposed model is dynamic and parameterized. It can be used in any marine system regardless the power level. To analyze the dynamic and/or steady state behavior of the proposed dry-type transformer, it has been evaluated in simulation using Matlab/Simulink.","PeriodicalId":370319,"journal":{"name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of Nonlinear Dry-Type Transformer for All-Electric Ship and Marine Applications\",\"authors\":\"B. Housseini, A. F. Okou, M. Tarbouchi, D. Bouchard, A. Zidan\",\"doi\":\"10.1109/IECON.2018.8591448\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a design of a high power nonlinear dry-type electric transformer used in All-Electric Ship (AES) and marine applications. Some nonlinear transformer models can be found in the literature. However, in these models, the effects of hysteresis and saturation in the core and windings are modeled using lookup table blocks. A lookup table, by definition, uses an array of data to map input values to output values, approximating a mathematical function. As the data array is static, the model is valid just for one defined transformer. The proposed model is dynamic and parameterized. It can be used in any marine system regardless the power level. To analyze the dynamic and/or steady state behavior of the proposed dry-type transformer, it has been evaluated in simulation using Matlab/Simulink.\",\"PeriodicalId\":370319,\"journal\":{\"name\":\"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2018.8591448\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2018.8591448","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种用于全电船舶和船舶的大功率非线性干式变压器的设计。在文献中可以找到一些非线性变压器模型。然而,在这些模型中,磁滞和饱和在铁芯和绕组中的影响是使用查找表块来建模的。根据定义,查找表使用数据数组将输入值映射到输出值,类似于数学函数。由于数据数组是静态的,因此该模型仅对一个已定义的转换器有效。该模型是动态的、参数化的。它可以用于任何船舶系统,无论功率水平。为了分析所提出的干式变压器的动态和/或稳态行为,使用Matlab/Simulink对其进行了仿真评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Nonlinear Dry-Type Transformer for All-Electric Ship and Marine Applications
This paper presents a design of a high power nonlinear dry-type electric transformer used in All-Electric Ship (AES) and marine applications. Some nonlinear transformer models can be found in the literature. However, in these models, the effects of hysteresis and saturation in the core and windings are modeled using lookup table blocks. A lookup table, by definition, uses an array of data to map input values to output values, approximating a mathematical function. As the data array is static, the model is valid just for one defined transformer. The proposed model is dynamic and parameterized. It can be used in any marine system regardless the power level. To analyze the dynamic and/or steady state behavior of the proposed dry-type transformer, it has been evaluated in simulation using Matlab/Simulink.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信