三维打印患者专用钻头导向治疗犬肱骨髁内裂的准确性。

T. G. Easter, A. Bilmont, J. Pink, B. Oxley
{"title":"三维打印患者专用钻头导向治疗犬肱骨髁内裂的准确性。","authors":"T. G. Easter, A. Bilmont, J. Pink, B. Oxley","doi":"10.1111/vsu.13346","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\nTo determine the accuracy of three-dimensional printed patient-specific drill guides (3D-PDG) as treatment of humeral intracondylar fissures (HIF) in dogs.\n\n\nSTUDY DESIGN\nRetrospective consecutive case series.\n\n\nANIMALS\nClient-owned dogs with HIF treated with a 5-mm transcondylar screw (TCS) placed from medial to lateral with a 3D-PDG.\n\n\nMETHODS\nThe proposed TCS entry point and trajectory were planned using computed tomography (CT) data and computer-aided design software (CAD), and a 3D-PDG was produced. During surgery the 3D-PDG was used to drill the pilot hole from medial to lateral; the guide was then removed, the pilot hole was overdrilled, and a 5-mm TCS was placed. Postoperative CT data were imported into CAD software, and the entry points, exit points, and trajectories were compared between the planned and actual screw locations.\n\n\nRESULTS\nSixteen elbows from 11 dogs were included. Mean (SD) entry point translation was 1.3 mm (0.64), with all screws entering cranial to the proposed location. Mean maximum screw angulation was 5.2° (2.10°), with most screws directed caudodistal to the desired trajectory. Mean (SD) exit point translation was 1.8 mm (0.89) from the planned location. There was no intra-articular screw placement.\n\n\nCONCLUSION\nUse of a 3D-PDG permitted accurate placement of a mediolateral 5-mm locking TCS within the humeral condyle.\n\n\nCLINICAL SIGNIFICANCE\nThree-dimensional printed patient-specific drill guides should be considered as accurate and consistent for placing TCS for treatment of HIF in dogs.","PeriodicalId":123280,"journal":{"name":"Veterinary surgery : VS","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure.\",\"authors\":\"T. G. Easter, A. Bilmont, J. Pink, B. Oxley\",\"doi\":\"10.1111/vsu.13346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE\\nTo determine the accuracy of three-dimensional printed patient-specific drill guides (3D-PDG) as treatment of humeral intracondylar fissures (HIF) in dogs.\\n\\n\\nSTUDY DESIGN\\nRetrospective consecutive case series.\\n\\n\\nANIMALS\\nClient-owned dogs with HIF treated with a 5-mm transcondylar screw (TCS) placed from medial to lateral with a 3D-PDG.\\n\\n\\nMETHODS\\nThe proposed TCS entry point and trajectory were planned using computed tomography (CT) data and computer-aided design software (CAD), and a 3D-PDG was produced. During surgery the 3D-PDG was used to drill the pilot hole from medial to lateral; the guide was then removed, the pilot hole was overdrilled, and a 5-mm TCS was placed. Postoperative CT data were imported into CAD software, and the entry points, exit points, and trajectories were compared between the planned and actual screw locations.\\n\\n\\nRESULTS\\nSixteen elbows from 11 dogs were included. Mean (SD) entry point translation was 1.3 mm (0.64), with all screws entering cranial to the proposed location. Mean maximum screw angulation was 5.2° (2.10°), with most screws directed caudodistal to the desired trajectory. Mean (SD) exit point translation was 1.8 mm (0.89) from the planned location. There was no intra-articular screw placement.\\n\\n\\nCONCLUSION\\nUse of a 3D-PDG permitted accurate placement of a mediolateral 5-mm locking TCS within the humeral condyle.\\n\\n\\nCLINICAL SIGNIFICANCE\\nThree-dimensional printed patient-specific drill guides should be considered as accurate and consistent for placing TCS for treatment of HIF in dogs.\",\"PeriodicalId\":123280,\"journal\":{\"name\":\"Veterinary surgery : VS\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary surgery : VS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/vsu.13346\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary surgery : VS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/vsu.13346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

目的探讨三维打印患者专用钻头导向(3D-PDG)治疗犬肱骨髁内裂(HIF)的准确性。研究设计:回顾性连续病例系列。动物科学家用3D-PDG从内侧到外侧放置5毫米经髁螺钉(TCS)治疗患有HIF的狗。方法利用计算机断层扫描(CT)数据和计算机辅助设计软件(CAD)规划TCS进入点和轨迹,并制作3D-PDG。术中使用3D-PDG从内侧向外侧钻导孔;然后取出导向器,超钻导孔,放置5mm TCS。将术后CT数据导入CAD软件,比较计划螺钉位置和实际螺钉位置的入钉点、出钉点和轨迹。结果纳入11只犬的16只肘部。平均(SD)进入点平移为1.3 mm(0.64),所有螺钉进入颅骨至建议位置。平均最大螺钉角度为5.2°(2.10°),大多数螺钉指向所需轨迹的尾远端。平均(SD)出口点距离计划位置为1.8 mm(0.89)。没有植入关节内螺钉。结论:使用3D-PDG可以在肱骨髁内准确放置5-mm内外侧锁定TCS。临床意义三维打印的患者特异性钻孔导轨对于放置TCS治疗犬HIF是准确和一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure.
OBJECTIVE To determine the accuracy of three-dimensional printed patient-specific drill guides (3D-PDG) as treatment of humeral intracondylar fissures (HIF) in dogs. STUDY DESIGN Retrospective consecutive case series. ANIMALS Client-owned dogs with HIF treated with a 5-mm transcondylar screw (TCS) placed from medial to lateral with a 3D-PDG. METHODS The proposed TCS entry point and trajectory were planned using computed tomography (CT) data and computer-aided design software (CAD), and a 3D-PDG was produced. During surgery the 3D-PDG was used to drill the pilot hole from medial to lateral; the guide was then removed, the pilot hole was overdrilled, and a 5-mm TCS was placed. Postoperative CT data were imported into CAD software, and the entry points, exit points, and trajectories were compared between the planned and actual screw locations. RESULTS Sixteen elbows from 11 dogs were included. Mean (SD) entry point translation was 1.3 mm (0.64), with all screws entering cranial to the proposed location. Mean maximum screw angulation was 5.2° (2.10°), with most screws directed caudodistal to the desired trajectory. Mean (SD) exit point translation was 1.8 mm (0.89) from the planned location. There was no intra-articular screw placement. CONCLUSION Use of a 3D-PDG permitted accurate placement of a mediolateral 5-mm locking TCS within the humeral condyle. CLINICAL SIGNIFICANCE Three-dimensional printed patient-specific drill guides should be considered as accurate and consistent for placing TCS for treatment of HIF in dogs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信