{"title":"轴向磁通在感应电动机电气故障检测中的应用","authors":"P. Ewert","doi":"10.1109/ISEM.2017.7993571","DOIUrl":null,"url":null,"abstract":"The article presents the possibility of using an axial flux in the detection of electrical faults in induction motors. The work presents results obtained for a faulty rotor squirrel cage and a stator winding short-circuit. Fault detection and identification is based on the analysis of symptoms obtained from the Fast Fourier Transform of a voltage induced by an axial flux in a measurement coil. The laboratory research was conducted on a small power induction motor using the LabView software.","PeriodicalId":286682,"journal":{"name":"2017 International Symposium on Electrical Machines (SME)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Use of axial flux in the detection of electrical faults in induction motors\",\"authors\":\"P. Ewert\",\"doi\":\"10.1109/ISEM.2017.7993571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article presents the possibility of using an axial flux in the detection of electrical faults in induction motors. The work presents results obtained for a faulty rotor squirrel cage and a stator winding short-circuit. Fault detection and identification is based on the analysis of symptoms obtained from the Fast Fourier Transform of a voltage induced by an axial flux in a measurement coil. The laboratory research was conducted on a small power induction motor using the LabView software.\",\"PeriodicalId\":286682,\"journal\":{\"name\":\"2017 International Symposium on Electrical Machines (SME)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Symposium on Electrical Machines (SME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEM.2017.7993571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Symposium on Electrical Machines (SME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEM.2017.7993571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Use of axial flux in the detection of electrical faults in induction motors
The article presents the possibility of using an axial flux in the detection of electrical faults in induction motors. The work presents results obtained for a faulty rotor squirrel cage and a stator winding short-circuit. Fault detection and identification is based on the analysis of symptoms obtained from the Fast Fourier Transform of a voltage induced by an axial flux in a measurement coil. The laboratory research was conducted on a small power induction motor using the LabView software.