基于故障定位的负序变化计算

V. Krcal, D. Topolanek
{"title":"基于故障定位的负序变化计算","authors":"V. Krcal, D. Topolanek","doi":"10.1109/EPE51172.2020.9269219","DOIUrl":null,"url":null,"abstract":"This paper is focused on calculation of negative sequence changes of voltage and current from distributed measurement. These changes are necessary for evaluation of a new fault localization method Vdip. A principle of changes calculation is described, and problems affiliated with phasor estimation are discussed. Solutions for suppressing major disturbances, such as frequency deviation and interharmonics, are suggested. A way of cancelling out interharmonics based on averaging in sliding windows is presented. Eventually, a calculation procedure is formed, and performance of individual proceedings is tested. The analysis shows that optimized setting of time frames, from which the changes are calculated, is essential to mitigate negative impacts of the major interharmonic frequencies, and can substitute utilization of digital filtering.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Negative Sequence Changes Calculation for Purposes of Fault Localization\",\"authors\":\"V. Krcal, D. Topolanek\",\"doi\":\"10.1109/EPE51172.2020.9269219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper is focused on calculation of negative sequence changes of voltage and current from distributed measurement. These changes are necessary for evaluation of a new fault localization method Vdip. A principle of changes calculation is described, and problems affiliated with phasor estimation are discussed. Solutions for suppressing major disturbances, such as frequency deviation and interharmonics, are suggested. A way of cancelling out interharmonics based on averaging in sliding windows is presented. Eventually, a calculation procedure is formed, and performance of individual proceedings is tested. The analysis shows that optimized setting of time frames, from which the changes are calculated, is essential to mitigate negative impacts of the major interharmonic frequencies, and can substitute utilization of digital filtering.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269219\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文主要研究分布式测量中电压和电流负序变化的计算。这些变化是评价一种新的断层定位方法Vdip所必需的。描述了变化量计算的原理,讨论了相量估计的相关问题。提出了抑制频率偏差和间谐波等主要干扰的解决方案。提出了一种基于滑动窗平均的互谐波消除方法。最后,形成了计算程序,并对各个程序的性能进行了测试。分析表明,优化时间框架的设置(由此计算变化)对于减轻主要间谐波频率的负面影响至关重要,并且可以替代数字滤波的使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Negative Sequence Changes Calculation for Purposes of Fault Localization
This paper is focused on calculation of negative sequence changes of voltage and current from distributed measurement. These changes are necessary for evaluation of a new fault localization method Vdip. A principle of changes calculation is described, and problems affiliated with phasor estimation are discussed. Solutions for suppressing major disturbances, such as frequency deviation and interharmonics, are suggested. A way of cancelling out interharmonics based on averaging in sliding windows is presented. Eventually, a calculation procedure is formed, and performance of individual proceedings is tested. The analysis shows that optimized setting of time frames, from which the changes are calculated, is essential to mitigate negative impacts of the major interharmonic frequencies, and can substitute utilization of digital filtering.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信