模糊遗传光容积脉搏波峰值检测

Reich Rechner D. Canlas, C. N. Ochotorena, E. Dadios
{"title":"模糊遗传光容积脉搏波峰值检测","authors":"Reich Rechner D. Canlas, C. N. Ochotorena, E. Dadios","doi":"10.1109/HNICEM.2014.7016243","DOIUrl":null,"url":null,"abstract":"Photoplethysmography (PPG) promises noninvasive body metrics measurement, especially that of heart rate. However, this system is prone to noise due to motion artifacts. This paper presents a fuzzy inference system, with membership functions and rules tuned by a genetic algorithm that utilizes the principal components of the PPG data accelerometer data from the x, y, and z coordinates in order to recover the peaks from the distorted PPG signal. A comparative test demonstrated that a 56.66% peak-to-peak correspondence to a reference ECG signal is achievable with the fuzzy-genetic system in place.","PeriodicalId":309548,"journal":{"name":"2014 International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment and Management (HNICEM)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Fuzzy-genetic photoplethysmograph peak detection\",\"authors\":\"Reich Rechner D. Canlas, C. N. Ochotorena, E. Dadios\",\"doi\":\"10.1109/HNICEM.2014.7016243\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Photoplethysmography (PPG) promises noninvasive body metrics measurement, especially that of heart rate. However, this system is prone to noise due to motion artifacts. This paper presents a fuzzy inference system, with membership functions and rules tuned by a genetic algorithm that utilizes the principal components of the PPG data accelerometer data from the x, y, and z coordinates in order to recover the peaks from the distorted PPG signal. A comparative test demonstrated that a 56.66% peak-to-peak correspondence to a reference ECG signal is achievable with the fuzzy-genetic system in place.\",\"PeriodicalId\":309548,\"journal\":{\"name\":\"2014 International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment and Management (HNICEM)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment and Management (HNICEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HNICEM.2014.7016243\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment and Management (HNICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HNICEM.2014.7016243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

光容积脉搏波描记术(PPG)有望实现无创的身体测量,尤其是心率测量。然而,由于运动伪影,该系统容易产生噪声。本文提出了一个模糊推理系统,其隶属函数和规则由遗传算法调整,该系统利用加速度计数据的x、y和z坐标的主成分来从失真的PPG信号中恢复峰值。对比实验表明,该模糊遗传系统与参考心电信号的峰对峰对应度达到56.66%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fuzzy-genetic photoplethysmograph peak detection
Photoplethysmography (PPG) promises noninvasive body metrics measurement, especially that of heart rate. However, this system is prone to noise due to motion artifacts. This paper presents a fuzzy inference system, with membership functions and rules tuned by a genetic algorithm that utilizes the principal components of the PPG data accelerometer data from the x, y, and z coordinates in order to recover the peaks from the distorted PPG signal. A comparative test demonstrated that a 56.66% peak-to-peak correspondence to a reference ECG signal is achievable with the fuzzy-genetic system in place.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信