{"title":"基于DSTATCOM的级联h桥变换器控制新策略","authors":"K. Anuradha, B. Muni, A. Rajkumar","doi":"10.1109/ICIIS.2006.365635","DOIUrl":null,"url":null,"abstract":"Reactive power management in a power distribution network of a power utility and industry plays a major role in reducing distribution loss, in maintaining constant distribution voltage and in improving power factor. The paper presents the simulation studies on a cascaded H-bridge converter based DSTATCOM for power factor improvement in power distribution set-up using load side compensation. In this novel control strategy, load reactive current is monitored and set as a reference for DSTATCOM controller in such a way that DSTATCOM is able to supply the reactive power demanded by the load both during steady state and transient conditions. For high power applications, cascaded H-bridge converter is the most ideal choice compared to neutral point clamped inverter and two-level inverter with series connected power devices.","PeriodicalId":227812,"journal":{"name":"2006 India International Conference on Power Electronics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Novel control strategy for cascaded H-bridge converter based DSTATCOM\",\"authors\":\"K. Anuradha, B. Muni, A. Rajkumar\",\"doi\":\"10.1109/ICIIS.2006.365635\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reactive power management in a power distribution network of a power utility and industry plays a major role in reducing distribution loss, in maintaining constant distribution voltage and in improving power factor. The paper presents the simulation studies on a cascaded H-bridge converter based DSTATCOM for power factor improvement in power distribution set-up using load side compensation. In this novel control strategy, load reactive current is monitored and set as a reference for DSTATCOM controller in such a way that DSTATCOM is able to supply the reactive power demanded by the load both during steady state and transient conditions. For high power applications, cascaded H-bridge converter is the most ideal choice compared to neutral point clamped inverter and two-level inverter with series connected power devices.\",\"PeriodicalId\":227812,\"journal\":{\"name\":\"2006 India International Conference on Power Electronics\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 India International Conference on Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIIS.2006.365635\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 India International Conference on Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIIS.2006.365635","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Novel control strategy for cascaded H-bridge converter based DSTATCOM
Reactive power management in a power distribution network of a power utility and industry plays a major role in reducing distribution loss, in maintaining constant distribution voltage and in improving power factor. The paper presents the simulation studies on a cascaded H-bridge converter based DSTATCOM for power factor improvement in power distribution set-up using load side compensation. In this novel control strategy, load reactive current is monitored and set as a reference for DSTATCOM controller in such a way that DSTATCOM is able to supply the reactive power demanded by the load both during steady state and transient conditions. For high power applications, cascaded H-bridge converter is the most ideal choice compared to neutral point clamped inverter and two-level inverter with series connected power devices.