Masykur Masykur, M. Saputra, F. Jayadi, Al Munawir, J. Supardi, Muazar Muazar
{"title":"Performa Solar Water Heater Collector Dengan Menggunakan Reflektor Dan Variasi Laju Aliran Air","authors":"Masykur Masykur, M. Saputra, F. Jayadi, Al Munawir, J. Supardi, Muazar Muazar","doi":"10.35308/jmkn.v8i2.6535","DOIUrl":null,"url":null,"abstract":"This study aims to look at the performance of the solar water heater collector with the addition of a reflector. Reflector is used to increase the absorption of solar radiation. The test was carried out by varying the water flow rate in the pipe, namely 75 l/hour, 150 l/hour and 225 l/hour with a collector tilt angle of 30°. Tests are carried out every one hour, starting at 09.00-16.00 WIB for each variation. Parameters measured in this study included glass temperature, inlet water temperature, outlet water temperature, pipe temperature, absorber temperature, ambient temperature and wind speed. The results showed that the highest efficiency occurred at a flow rate of 225 l/hour, which was 62.44% at IT 3,366 MJ/m2, and the highest ratio of outlet water temperature and inlet water temperature was 1.51 at a flow rate of 75l/h. Adding a reflector to the coverslip can increase collector efficiency.","PeriodicalId":166109,"journal":{"name":"Jurnal Mekanova : Mekanikal, Inovasi dan Teknologi","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Mekanova : Mekanikal, Inovasi dan Teknologi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35308/jmkn.v8i2.6535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是观察太阳能热水器集热器的性能增加了一个反射器。反射器用来增加对太阳辐射的吸收。在集热器倾角为30°的情况下,通过改变管道内的流量,即75 l/小时、150 l/小时和225 l/小时进行试验。每小时进行一次测试,从上午9点到下午16点对每个变异进行测试。本研究测量的参数包括玻璃温度、进水温度、出水温度、管道温度、吸收器温度、环境温度和风速。结果表明:在流量为225 l/h时效率最高,在流量为3366 MJ/m2时效率为62.44%;在流量为75l/h时,出水温度与进水温度之比最高,为1.51;在盖盖上加一个反射器可以提高集热器的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performa Solar Water Heater Collector Dengan Menggunakan Reflektor Dan Variasi Laju Aliran Air
This study aims to look at the performance of the solar water heater collector with the addition of a reflector. Reflector is used to increase the absorption of solar radiation. The test was carried out by varying the water flow rate in the pipe, namely 75 l/hour, 150 l/hour and 225 l/hour with a collector tilt angle of 30°. Tests are carried out every one hour, starting at 09.00-16.00 WIB for each variation. Parameters measured in this study included glass temperature, inlet water temperature, outlet water temperature, pipe temperature, absorber temperature, ambient temperature and wind speed. The results showed that the highest efficiency occurred at a flow rate of 225 l/hour, which was 62.44% at IT 3,366 MJ/m2, and the highest ratio of outlet water temperature and inlet water temperature was 1.51 at a flow rate of 75l/h. Adding a reflector to the coverslip can increase collector efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信