Der-fa Chen, Khiem Nguyen-Duy, Tian‐Hua Liu, M. Andersen
{"title":"无冗余功率器件的矩阵变换器驱动系统双开开关故障容错调制方法","authors":"Der-fa Chen, Khiem Nguyen-Duy, Tian‐Hua Liu, M. Andersen","doi":"10.1109/ASSCC.2012.6523240","DOIUrl":null,"url":null,"abstract":"This paper studies the double open-switch fault issue occurring within the conventional matrix converter driving a three-phase permanent-magnet synchronous motor system and proposes a fault-tolerant solution by introducing a revised modulation strategy. In this switching strategy, the rectifier-stage modulation is adjusted based on the knowledge of the switching logics of the inverter-stage and the operating input voltage sectors. However, the proposed fault-tolerant method does not rely on the assist of any redundant power devices or any reconfiguration of the matrix converter circuit by means of using redundant physical connections. It is shown that different locations of the double open switch affect the availability of the revised modulation. The steady state absolute speed error achieved with the proposed method is 4% of the nominal speed. Experimental results are performed to demonstrate the efficacy of the proposed methods.","PeriodicalId":341348,"journal":{"name":"2012 10th International Power & Energy Conference (IPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A fault-tolerant modulation method to counteract the double open-switch fault in matrix converter drive systems without redundant power devices\",\"authors\":\"Der-fa Chen, Khiem Nguyen-Duy, Tian‐Hua Liu, M. Andersen\",\"doi\":\"10.1109/ASSCC.2012.6523240\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper studies the double open-switch fault issue occurring within the conventional matrix converter driving a three-phase permanent-magnet synchronous motor system and proposes a fault-tolerant solution by introducing a revised modulation strategy. In this switching strategy, the rectifier-stage modulation is adjusted based on the knowledge of the switching logics of the inverter-stage and the operating input voltage sectors. However, the proposed fault-tolerant method does not rely on the assist of any redundant power devices or any reconfiguration of the matrix converter circuit by means of using redundant physical connections. It is shown that different locations of the double open switch affect the availability of the revised modulation. The steady state absolute speed error achieved with the proposed method is 4% of the nominal speed. Experimental results are performed to demonstrate the efficacy of the proposed methods.\",\"PeriodicalId\":341348,\"journal\":{\"name\":\"2012 10th International Power & Energy Conference (IPEC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 10th International Power & Energy Conference (IPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2012.6523240\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th International Power & Energy Conference (IPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2012.6523240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A fault-tolerant modulation method to counteract the double open-switch fault in matrix converter drive systems without redundant power devices
This paper studies the double open-switch fault issue occurring within the conventional matrix converter driving a three-phase permanent-magnet synchronous motor system and proposes a fault-tolerant solution by introducing a revised modulation strategy. In this switching strategy, the rectifier-stage modulation is adjusted based on the knowledge of the switching logics of the inverter-stage and the operating input voltage sectors. However, the proposed fault-tolerant method does not rely on the assist of any redundant power devices or any reconfiguration of the matrix converter circuit by means of using redundant physical connections. It is shown that different locations of the double open switch affect the availability of the revised modulation. The steady state absolute speed error achieved with the proposed method is 4% of the nominal speed. Experimental results are performed to demonstrate the efficacy of the proposed methods.