IEEE 841 1994与2001的比较——下一个修订周期该标准将走向何方?

J. Holmquist, J. Malinowski
{"title":"IEEE 841 1994与2001的比较——下一个修订周期该标准将走向何方?","authors":"J. Holmquist, J. Malinowski","doi":"10.1109/PAPCON.2004.1338355","DOIUrl":null,"url":null,"abstract":"This paper discusses the changes that took place when the IEEE Standard for Petroleum and Chemical Industry - severe duty totally enclosed fan-cooled (TEFC) squirrel cage induction motors - up to and including 370 kW (500 hp) was changed from the 1994 to the 2001 revision. Ideas for the next revision cycle will be introduced for consideration.","PeriodicalId":189773,"journal":{"name":"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of IEEE 841 1994 to 2001 - where might the standard go on the next revision cycle?\",\"authors\":\"J. Holmquist, J. Malinowski\",\"doi\":\"10.1109/PAPCON.2004.1338355\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the changes that took place when the IEEE Standard for Petroleum and Chemical Industry - severe duty totally enclosed fan-cooled (TEFC) squirrel cage induction motors - up to and including 370 kW (500 hp) was changed from the 1994 to the 2001 revision. Ideas for the next revision cycle will be introduced for consideration.\",\"PeriodicalId\":189773,\"journal\":{\"name\":\"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAPCON.2004.1338355\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 2004 Annual Pulp and Paper Industry Technical Conference (IEEE Cat. No.04CH37523)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.2004.1338355","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了IEEE石油和化学工业标准——大功率全封闭风扇冷却(TEFC)鼠笼式感应电动机——从1994年到2001年的修订中发生的变化。将介绍下一个修订周期的想法供审议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of IEEE 841 1994 to 2001 - where might the standard go on the next revision cycle?
This paper discusses the changes that took place when the IEEE Standard for Petroleum and Chemical Industry - severe duty totally enclosed fan-cooled (TEFC) squirrel cage induction motors - up to and including 370 kW (500 hp) was changed from the 1994 to the 2001 revision. Ideas for the next revision cycle will be introduced for consideration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信