基于改进线路注入技术的三相整流器谐波电流降低

H.I. Zynal, Shawkat Mohammed Younis
{"title":"基于改进线路注入技术的三相整流器谐波电流降低","authors":"H.I. Zynal, Shawkat Mohammed Younis","doi":"10.1109/ICECCPCE.2013.6998763","DOIUrl":null,"url":null,"abstract":"This paper presents a modified line injection technique to reduce the input line current harmonics generated by three-phase AC/DC rectifiers. In conventional harmonic current injection method the optimum harmonic current reduction is obtained when (root mean square) (rms) value of the injection third harmonic current equals the DC load current. Therefore the power diode peak current is increased by 72 % compared to without injection case. In this paper a modified harmonic current injection is applied using a three-bidirectional switches connected to the input lines of the rectifier. The switch that is connected to line with zero current will be turned on to inject the harmonic current to it . In this method optimum harmonic reduction is obtained when the injection third harmonic current equal , one third of the DC load current. Therefore the power diode peak current is increased by 23.5% only and total harmonic distortion (THD) of the input current is less than 5% is obtained.","PeriodicalId":226378,"journal":{"name":"2013 International Conference on Electrical Communication, Computer, Power, and Control Engineering (ICECCPCE)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Harmonic current reduction of three-phase rectifier based on modified line injection technique\",\"authors\":\"H.I. Zynal, Shawkat Mohammed Younis\",\"doi\":\"10.1109/ICECCPCE.2013.6998763\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a modified line injection technique to reduce the input line current harmonics generated by three-phase AC/DC rectifiers. In conventional harmonic current injection method the optimum harmonic current reduction is obtained when (root mean square) (rms) value of the injection third harmonic current equals the DC load current. Therefore the power diode peak current is increased by 72 % compared to without injection case. In this paper a modified harmonic current injection is applied using a three-bidirectional switches connected to the input lines of the rectifier. The switch that is connected to line with zero current will be turned on to inject the harmonic current to it . In this method optimum harmonic reduction is obtained when the injection third harmonic current equal , one third of the DC load current. Therefore the power diode peak current is increased by 23.5% only and total harmonic distortion (THD) of the input current is less than 5% is obtained.\",\"PeriodicalId\":226378,\"journal\":{\"name\":\"2013 International Conference on Electrical Communication, Computer, Power, and Control Engineering (ICECCPCE)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Conference on Electrical Communication, Computer, Power, and Control Engineering (ICECCPCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECCPCE.2013.6998763\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Electrical Communication, Computer, Power, and Control Engineering (ICECCPCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECCPCE.2013.6998763","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种改进的线路注入技术,以降低三相交直流整流器产生的输入线路电流谐波。在传统的谐波电流注入方法中,当注入三次谐波电流的均方根值等于直流负载电流时,谐波电流减小最佳。因此,功率二极管的峰值电流比没有注入的情况下增加了72%。本文采用了一种改进的谐波电流注入方法,该方法采用了连接在整流器输入线上的三双向开关。接通接通零电流线路的开关,向其注入谐波电流。当注入三次谐波电流等于直流负载电流的三分之一时,该方法得到了最优的谐波抑制。因此,功率二极管的峰值电流仅增加了23.5%,而输入电流的总谐波失真(THD)小于5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Harmonic current reduction of three-phase rectifier based on modified line injection technique
This paper presents a modified line injection technique to reduce the input line current harmonics generated by three-phase AC/DC rectifiers. In conventional harmonic current injection method the optimum harmonic current reduction is obtained when (root mean square) (rms) value of the injection third harmonic current equals the DC load current. Therefore the power diode peak current is increased by 72 % compared to without injection case. In this paper a modified harmonic current injection is applied using a three-bidirectional switches connected to the input lines of the rectifier. The switch that is connected to line with zero current will be turned on to inject the harmonic current to it . In this method optimum harmonic reduction is obtained when the injection third harmonic current equal , one third of the DC load current. Therefore the power diode peak current is increased by 23.5% only and total harmonic distortion (THD) of the input current is less than 5% is obtained.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信