{"title":"[用Condylocomp LR 2获得的记录的再现性研究]。","authors":"K H Ott, L E Olavarria, M Bose","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The reproducibility of movement recordings obtained with the Condylocomp LR 2 was tested on three different types of articulator (Dentatus, SAM 2, Stuart). Additionally, reproducibility of TMJ movement recordings was tested on 18 subjects. Differences of +/- 2 degrees to the real angles, when working carefully, seem to be precise enough. The Condylocomp LR 2 seems to be a useful means for diagnosing and documenting TMJ movements, because it allows dynamic recordings with high resolution and correction of geometric errors.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 9","pages":"596-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Studies on the reproducibility of recordings obtained with the Condylocomp LR 2].\",\"authors\":\"K H Ott, L E Olavarria, M Bose\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The reproducibility of movement recordings obtained with the Condylocomp LR 2 was tested on three different types of articulator (Dentatus, SAM 2, Stuart). Additionally, reproducibility of TMJ movement recordings was tested on 18 subjects. Differences of +/- 2 degrees to the real angles, when working carefully, seem to be precise enough. The Condylocomp LR 2 seems to be a useful means for diagnosing and documenting TMJ movements, because it allows dynamic recordings with high resolution and correction of geometric errors.</p>\",\"PeriodicalId\":11244,\"journal\":{\"name\":\"Deutsche zahnarztliche Zeitschrift\",\"volume\":\"46 9\",\"pages\":\"596-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Deutsche zahnarztliche Zeitschrift\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在三种不同类型的关节(Dentatus, SAM 2, Stuart)上测试了用Condylocomp LR 2获得的运动记录的再现性。此外,对18名被试进行了TMJ运动记录的再现性测试。与实际角度+/- 2度的差异,如果仔细计算,似乎足够精确。Condylocomp LR 2似乎是诊断和记录TMJ运动的有用手段,因为它允许高分辨率的动态记录和几何误差校正。
[Studies on the reproducibility of recordings obtained with the Condylocomp LR 2].
The reproducibility of movement recordings obtained with the Condylocomp LR 2 was tested on three different types of articulator (Dentatus, SAM 2, Stuart). Additionally, reproducibility of TMJ movement recordings was tested on 18 subjects. Differences of +/- 2 degrees to the real angles, when working carefully, seem to be precise enough. The Condylocomp LR 2 seems to be a useful means for diagnosing and documenting TMJ movements, because it allows dynamic recordings with high resolution and correction of geometric errors.