非接触式生命体征检测中准确心率测量的呼吸谐波消除

Jianxuan Tu, Jenshan Lin
{"title":"非接触式生命体征检测中准确心率测量的呼吸谐波消除","authors":"Jianxuan Tu, Jenshan Lin","doi":"10.1109/MWSYM.2013.6697732","DOIUrl":null,"url":null,"abstract":"Measuring the respiration rate (RR) and heart rate (HR) simultaneously in non-contact vital sign detection requires large dynamic range which is caused by large difference in respiratory and heart induced displacements. Generated by the demodulation method and displacements, the higher order harmonics of RR near HR might appear and cause error in HR measurement. A respiration harmonics cancellation method is proposed to eliminate the interference. Experiments are performed by a 5.8-GHz non-contact Doppler radar vital sign detection system with an S12 Any-Touch ECG-Accurate Heart Rate Monitor as the reference to verify the method. HR is measured by searching the highest peak within the typical HR range in the frequency spectrum. Results of HR measurement with and without the respiration harmonics cancellation method are compared. When the harmonics of the respiration signal are strong, using the respiration harmonics cancellation method reduces the average error from 15.9% to 3.2%.","PeriodicalId":128968,"journal":{"name":"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"44","resultStr":"{\"title\":\"Respiration harmonics cancellation for Accurate Heart Rate measurement in non-contact vital sign detection\",\"authors\":\"Jianxuan Tu, Jenshan Lin\",\"doi\":\"10.1109/MWSYM.2013.6697732\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measuring the respiration rate (RR) and heart rate (HR) simultaneously in non-contact vital sign detection requires large dynamic range which is caused by large difference in respiratory and heart induced displacements. Generated by the demodulation method and displacements, the higher order harmonics of RR near HR might appear and cause error in HR measurement. A respiration harmonics cancellation method is proposed to eliminate the interference. Experiments are performed by a 5.8-GHz non-contact Doppler radar vital sign detection system with an S12 Any-Touch ECG-Accurate Heart Rate Monitor as the reference to verify the method. HR is measured by searching the highest peak within the typical HR range in the frequency spectrum. Results of HR measurement with and without the respiration harmonics cancellation method are compared. When the harmonics of the respiration signal are strong, using the respiration harmonics cancellation method reduces the average error from 15.9% to 3.2%.\",\"PeriodicalId\":128968,\"journal\":{\"name\":\"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"44\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2013.6697732\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2013.6697732","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 44

摘要

在非接触式生命体征检测中,同时测量呼吸速率(RR)和心率(HR)需要较大的动态范围,这是由于呼吸位移和心脏位移差异较大造成的。由于解调方法和位移的影响,在HR附近可能出现高次谐波,导致HR测量误差。为了消除干扰,提出了一种呼吸谐波对消方法。在5.8 ghz非接触式多普勒雷达生命体征检测系统上,以S12型任意触控心电图精确心率监测仪为参考,进行了实验验证。通过在频谱中搜索典型HR范围内的峰值来测量HR。比较了采用呼吸谐波对消法和不采用呼吸谐波对消法的HR测量结果。当呼吸信号的谐波较强时,采用呼吸谐波对消方法将平均误差从15.9%降低到3.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Respiration harmonics cancellation for Accurate Heart Rate measurement in non-contact vital sign detection
Measuring the respiration rate (RR) and heart rate (HR) simultaneously in non-contact vital sign detection requires large dynamic range which is caused by large difference in respiratory and heart induced displacements. Generated by the demodulation method and displacements, the higher order harmonics of RR near HR might appear and cause error in HR measurement. A respiration harmonics cancellation method is proposed to eliminate the interference. Experiments are performed by a 5.8-GHz non-contact Doppler radar vital sign detection system with an S12 Any-Touch ECG-Accurate Heart Rate Monitor as the reference to verify the method. HR is measured by searching the highest peak within the typical HR range in the frequency spectrum. Results of HR measurement with and without the respiration harmonics cancellation method are compared. When the harmonics of the respiration signal are strong, using the respiration harmonics cancellation method reduces the average error from 15.9% to 3.2%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信