{"title":"一种基于矩阵变换器的三相公用电源","authors":"P. Zanchetta, P. Wheeler, L. Empringham, J. Clare","doi":"10.1049/IET-PEL:20070277","DOIUrl":null,"url":null,"abstract":"A matrix converter and variable-speed diesel generator are integrated to create a three-phase utility power supply. The matrix converter is designed to meet tight harmonic and transient response requirements while allowing variable voltage and frequency input from the generator's permanent magnet alternator; This enables the generator to provide stable power over a range of engine speeds and load conditions. Test results for the 10 kW offline power supply are provided to demonstrate system performance.","PeriodicalId":131410,"journal":{"name":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"42","resultStr":"{\"title\":\"A three-phase utility power supply based on the matrix converter\",\"authors\":\"P. Zanchetta, P. Wheeler, L. Empringham, J. Clare\",\"doi\":\"10.1049/IET-PEL:20070277\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A matrix converter and variable-speed diesel generator are integrated to create a three-phase utility power supply. The matrix converter is designed to meet tight harmonic and transient response requirements while allowing variable voltage and frequency input from the generator's permanent magnet alternator; This enables the generator to provide stable power over a range of engine speeds and load conditions. Test results for the 10 kW offline power supply are provided to demonstrate system performance.\",\"PeriodicalId\":131410,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/IET-PEL:20070277\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/IET-PEL:20070277","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A three-phase utility power supply based on the matrix converter
A matrix converter and variable-speed diesel generator are integrated to create a three-phase utility power supply. The matrix converter is designed to meet tight harmonic and transient response requirements while allowing variable voltage and frequency input from the generator's permanent magnet alternator; This enables the generator to provide stable power over a range of engine speeds and load conditions. Test results for the 10 kW offline power supply are provided to demonstrate system performance.