方波逆变器在不同导通方式下的THD比较分析

Ranitesh Gupta, K. Sahay
{"title":"方波逆变器在不同导通方式下的THD比较分析","authors":"Ranitesh Gupta, K. Sahay","doi":"10.11591/ijape.v12.i3.pp312-320","DOIUrl":null,"url":null,"abstract":"This paper proposes conduction schemes for the most common six-switch voltage sources inverter. Also, a comparative study of the output THD for different conduction modes of switches for a three-phase square wave inverter is done, as the harmonic content of any electrical system is important to analyze its performance. The harmonic distortion of the load voltage and load current is taken as the main constraint to evaluate the performance of the three-phase inverter. So, control strategies for various loads are executed for different modulation schemes of inverter switches using MATLAB/Simulink software. Obtained results show that 150° conduction gives the least THD for output current, and 170° conduction gives the least THD for output voltage for three-phase inverters. Also, harmonic contents are reduced using a passive LC filter at the output of the inverter.","PeriodicalId":340072,"journal":{"name":"International Journal of Applied Power Engineering (IJAPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative analysis of THD for square-wave inverter at different conduction modes\",\"authors\":\"Ranitesh Gupta, K. Sahay\",\"doi\":\"10.11591/ijape.v12.i3.pp312-320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes conduction schemes for the most common six-switch voltage sources inverter. Also, a comparative study of the output THD for different conduction modes of switches for a three-phase square wave inverter is done, as the harmonic content of any electrical system is important to analyze its performance. The harmonic distortion of the load voltage and load current is taken as the main constraint to evaluate the performance of the three-phase inverter. So, control strategies for various loads are executed for different modulation schemes of inverter switches using MATLAB/Simulink software. Obtained results show that 150° conduction gives the least THD for output current, and 170° conduction gives the least THD for output voltage for three-phase inverters. Also, harmonic contents are reduced using a passive LC filter at the output of the inverter.\",\"PeriodicalId\":340072,\"journal\":{\"name\":\"International Journal of Applied Power Engineering (IJAPE)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering (IJAPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/ijape.v12.i3.pp312-320\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering (IJAPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijape.v12.i3.pp312-320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了最常见的六开关电压源逆变器的导通方案。同时,对三相方波逆变器开关不同导通方式下的输出THD进行了对比研究,因为任何电力系统的谐波含量都是分析其性能的重要因素。将负载电压和负载电流的谐波畸变作为评价三相逆变器性能的主要约束条件。因此,利用MATLAB/Simulink软件对逆变器开关的不同调制方案执行不同负载的控制策略。所得结果表明,三相逆变器的输出电流在150°导通时THD最小,输出电压在170°导通时THD最小。此外,在逆变器的输出端使用无源LC滤波器减少谐波含量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative analysis of THD for square-wave inverter at different conduction modes
This paper proposes conduction schemes for the most common six-switch voltage sources inverter. Also, a comparative study of the output THD for different conduction modes of switches for a three-phase square wave inverter is done, as the harmonic content of any electrical system is important to analyze its performance. The harmonic distortion of the load voltage and load current is taken as the main constraint to evaluate the performance of the three-phase inverter. So, control strategies for various loads are executed for different modulation schemes of inverter switches using MATLAB/Simulink software. Obtained results show that 150° conduction gives the least THD for output current, and 170° conduction gives the least THD for output voltage for three-phase inverters. Also, harmonic contents are reduced using a passive LC filter at the output of the inverter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信