讽刺补丁:一种可穿戴设备,用于植入系统的远程供电和连接

J. Olivo, S. Carrara, G. Micheli
{"title":"讽刺补丁:一种可穿戴设备,用于植入系统的远程供电和连接","authors":"J. Olivo, S. Carrara, G. Micheli","doi":"10.1109/I2MTC.2012.6229168","DOIUrl":null,"url":null,"abstract":"A wearable device to power implanted sensors by means of an inductive link is presented. The system, having size 69 × 40 mm2, is designed to be embedded into a skin patch and located over the implantation area. The system can transfer up to 15 mW within 6 mm in air. Tested with a 17 mm thick beef sirloin placed between the inductors, the device is able to deliver up to 1.17 mW. Downlink communication with the implanted sensors is performed at 100 kbps by using amplitude modulation. Uplink communication is performed at 66.6 kbps by using load modulation. Long range communication between the system and remote devices is enabled by a bluetooth module. The system is powered by two rechargeable lithium-ion polymer batteries and has an autonomy of 10 h in stand-by mode and about 1.5 h in transmitting mode.","PeriodicalId":387839,"journal":{"name":"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"IronIC patch: A wearable device for the remote powering and connectivity of implantable systems\",\"authors\":\"J. Olivo, S. Carrara, G. Micheli\",\"doi\":\"10.1109/I2MTC.2012.6229168\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A wearable device to power implanted sensors by means of an inductive link is presented. The system, having size 69 × 40 mm2, is designed to be embedded into a skin patch and located over the implantation area. The system can transfer up to 15 mW within 6 mm in air. Tested with a 17 mm thick beef sirloin placed between the inductors, the device is able to deliver up to 1.17 mW. Downlink communication with the implanted sensors is performed at 100 kbps by using amplitude modulation. Uplink communication is performed at 66.6 kbps by using load modulation. Long range communication between the system and remote devices is enabled by a bluetooth module. The system is powered by two rechargeable lithium-ion polymer batteries and has an autonomy of 10 h in stand-by mode and about 1.5 h in transmitting mode.\",\"PeriodicalId\":387839,\"journal\":{\"name\":\"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC.2012.6229168\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2012.6229168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

提出了一种通过感应链路为植入传感器供电的可穿戴设备。该系统的尺寸为69 × 40 mm2,设计用于嵌入皮肤贴片并位于植入区域上方。该系统可以在6毫米的空气中传输高达15兆瓦的功率。在电感器之间放置17毫米厚的牛里脊肉进行测试,该设备能够提供高达1.17 mW的功率。通过使用调幅,以100kbps的速度与植入的传感器进行下行通信。上行通信采用负载调制,速率为66.6 kbps。系统与远程设备之间的远程通信通过蓝牙模块实现。该系统由两节可充电锂离子聚合物电池供电,在待机模式下具有10小时的自主性,在传输模式下具有约1.5小时的自主性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
IronIC patch: A wearable device for the remote powering and connectivity of implantable systems
A wearable device to power implanted sensors by means of an inductive link is presented. The system, having size 69 × 40 mm2, is designed to be embedded into a skin patch and located over the implantation area. The system can transfer up to 15 mW within 6 mm in air. Tested with a 17 mm thick beef sirloin placed between the inductors, the device is able to deliver up to 1.17 mW. Downlink communication with the implanted sensors is performed at 100 kbps by using amplitude modulation. Uplink communication is performed at 66.6 kbps by using load modulation. Long range communication between the system and remote devices is enabled by a bluetooth module. The system is powered by two rechargeable lithium-ion polymer batteries and has an autonomy of 10 h in stand-by mode and about 1.5 h in transmitting mode.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信