机电速度图开发使用FNET/GridEye频率测量

P. Markham, Yilu Liu
{"title":"机电速度图开发使用FNET/GridEye频率测量","authors":"P. Markham, Yilu Liu","doi":"10.1109/PESGM.2014.6939807","DOIUrl":null,"url":null,"abstract":"Differences in electromechanical wave propagation speeds have long been observed in different regions of the power grid. Various attempts have been made over the years to develop “speed maps” of the grid, either through analytical means or from measurements. Analytical techniques are computationally difficult and require that an accurate model of the system be known a priori, which is generally impossible for a large system such as the Eastern Interconnection. Most, if not all, of measurement-based techniques introduced to-date assume constant propagation speed between the disturbance source and the sensor, which does not reflect reality. This paper presents a new method for developing speed maps using FNET/GridEye data from confirmed disturbances that seeks to eliminate many of the issues faced by previous attempts.","PeriodicalId":149134,"journal":{"name":"2014 IEEE PES General Meeting | Conference & Exposition","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Electromechanical speed map development using FNET/GridEye frequency measurements\",\"authors\":\"P. Markham, Yilu Liu\",\"doi\":\"10.1109/PESGM.2014.6939807\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Differences in electromechanical wave propagation speeds have long been observed in different regions of the power grid. Various attempts have been made over the years to develop “speed maps” of the grid, either through analytical means or from measurements. Analytical techniques are computationally difficult and require that an accurate model of the system be known a priori, which is generally impossible for a large system such as the Eastern Interconnection. Most, if not all, of measurement-based techniques introduced to-date assume constant propagation speed between the disturbance source and the sensor, which does not reflect reality. This paper presents a new method for developing speed maps using FNET/GridEye data from confirmed disturbances that seeks to eliminate many of the issues faced by previous attempts.\",\"PeriodicalId\":149134,\"journal\":{\"name\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2014.6939807\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES General Meeting | Conference & Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2014.6939807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

在电网的不同区域,早已观察到机电波传播速度的差异。多年来,通过分析方法或测量方法,已经进行了各种尝试,以开发网格的“速度图”。分析技术在计算上是困难的,并且需要先验地知道系统的准确模型,这对于像东部互联这样的大型系统通常是不可能的。迄今为止,大多数(如果不是全部的话)基于测量的技术都假设干扰源和传感器之间的传播速度是恒定的,这与现实情况不符。本文提出了一种利用已确认扰动的FNET/GridEye数据开发速度图的新方法,旨在消除以前尝试面临的许多问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electromechanical speed map development using FNET/GridEye frequency measurements
Differences in electromechanical wave propagation speeds have long been observed in different regions of the power grid. Various attempts have been made over the years to develop “speed maps” of the grid, either through analytical means or from measurements. Analytical techniques are computationally difficult and require that an accurate model of the system be known a priori, which is generally impossible for a large system such as the Eastern Interconnection. Most, if not all, of measurement-based techniques introduced to-date assume constant propagation speed between the disturbance source and the sensor, which does not reflect reality. This paper presents a new method for developing speed maps using FNET/GridEye data from confirmed disturbances that seeks to eliminate many of the issues faced by previous attempts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信