{"title":"利用实时状态估计方法检测径向配电系统变电点的非技术损耗","authors":"R.V. Cruz, C.V. Quintero, F. Pérez","doi":"10.1109/TDCLA.2006.311416","DOIUrl":null,"url":null,"abstract":"Conventional studies aimed at detecting non-technical losses in electrical energy distribution systems are based on performing energy balances in each substation, circuit or transformation point. Energy balances in transformation points allow us to focalize losses. However, we would have to make measurements in each transformer in order to compare the amount of energy that has been delivered with the energy that has been billed. The EDC system contains over 15,000 transformation points. Therefore, it would be extremely complicated, both from the technical and economic point of view, to make measurements in each of these devices. This paper describes a state estimation methodology in real time for each transformation point. This allows us to determine the areas with the greatest amount of nontechnical losses across the radial distribution system. An example of the application of this methodology is provided using a real 12.47 kV distribution circuit with 20 transformation points","PeriodicalId":406067,"journal":{"name":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Detecting Non-Technical Losses in Radial Distribution System Transformation Point through the Real Time State Estimation Method\",\"authors\":\"R.V. Cruz, C.V. Quintero, F. Pérez\",\"doi\":\"10.1109/TDCLA.2006.311416\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conventional studies aimed at detecting non-technical losses in electrical energy distribution systems are based on performing energy balances in each substation, circuit or transformation point. Energy balances in transformation points allow us to focalize losses. However, we would have to make measurements in each transformer in order to compare the amount of energy that has been delivered with the energy that has been billed. The EDC system contains over 15,000 transformation points. Therefore, it would be extremely complicated, both from the technical and economic point of view, to make measurements in each of these devices. This paper describes a state estimation methodology in real time for each transformation point. This allows us to determine the areas with the greatest amount of nontechnical losses across the radial distribution system. An example of the application of this methodology is provided using a real 12.47 kV distribution circuit with 20 transformation points\",\"PeriodicalId\":406067,\"journal\":{\"name\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDCLA.2006.311416\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLA.2006.311416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

旨在检测电能分配系统非技术损失的传统研究是基于在每个变电站、电路或转换点进行能量平衡。转换点的能量平衡使我们能够集中损失。然而,我们必须在每个变压器中进行测量,以便比较已交付的能量与已计费的能量。EDC系统包含超过15,000个转换点。因此,从技术和经济的角度来看,在这些设备中进行测量将是极其复杂的。本文描述了一种针对每个转换点的实时状态估计方法。这使我们能够确定整个径向配电系统中非技术损耗最大的区域。给出了一个实际的12.47 kV、20个变换点的配电线路的应用实例
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detecting Non-Technical Losses in Radial Distribution System Transformation Point through the Real Time State Estimation Method
Conventional studies aimed at detecting non-technical losses in electrical energy distribution systems are based on performing energy balances in each substation, circuit or transformation point. Energy balances in transformation points allow us to focalize losses. However, we would have to make measurements in each transformer in order to compare the amount of energy that has been delivered with the energy that has been billed. The EDC system contains over 15,000 transformation points. Therefore, it would be extremely complicated, both from the technical and economic point of view, to make measurements in each of these devices. This paper describes a state estimation methodology in real time for each transformation point. This allows us to determine the areas with the greatest amount of nontechnical losses across the radial distribution system. An example of the application of this methodology is provided using a real 12.47 kV distribution circuit with 20 transformation points
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信