空间矢量摆振法诊断IPM同步电机定子短路故障

Jiangbiao He, Andrew P. Strandt, Alia Manarik, Peng Zhang, N. Demerdash
{"title":"空间矢量摆振法诊断IPM同步电机定子短路故障","authors":"Jiangbiao He, Andrew P. Strandt, Alia Manarik, Peng Zhang, N. Demerdash","doi":"10.1109/IEMDC.2013.6556174","DOIUrl":null,"url":null,"abstract":"Experimental characterization of interior permanent magnet (IPM) synchronous machines experiencing winding short-circuit faults is necessary in developing diagnostics indices to be used in detecting short-circuit winding faults. Known fault indices include the current spectrum analysis, the negative-sequence components method, and the space-vector based pendulous oscillation method. This paper applies all three methods to experimental turn-to-turn short-circuit fault data acquired from a 3.5 hp IPM motor energized by a PWM voltage source inverter. The results are compared and analyzed, and since none of the three methods presented unambiguously demonstrate the existence of a winding short-circuit fault, the practical difficulties of short-circuit fault detection and mitigation are discussed in that light.","PeriodicalId":199452,"journal":{"name":"2013 International Electric Machines & Drives Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Diagnosis of stator short-circuit faults in an IPM synchronous machine using a space-vector pendulous oscillation method\",\"authors\":\"Jiangbiao He, Andrew P. Strandt, Alia Manarik, Peng Zhang, N. Demerdash\",\"doi\":\"10.1109/IEMDC.2013.6556174\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experimental characterization of interior permanent magnet (IPM) synchronous machines experiencing winding short-circuit faults is necessary in developing diagnostics indices to be used in detecting short-circuit winding faults. Known fault indices include the current spectrum analysis, the negative-sequence components method, and the space-vector based pendulous oscillation method. This paper applies all three methods to experimental turn-to-turn short-circuit fault data acquired from a 3.5 hp IPM motor energized by a PWM voltage source inverter. The results are compared and analyzed, and since none of the three methods presented unambiguously demonstrate the existence of a winding short-circuit fault, the practical difficulties of short-circuit fault detection and mitigation are discussed in that light.\",\"PeriodicalId\":199452,\"journal\":{\"name\":\"2013 International Electric Machines & Drives Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Electric Machines & Drives Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMDC.2013.6556174\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Electric Machines & Drives Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMDC.2013.6556174","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

内部永磁同步电机绕组短路故障的实验表征是建立绕组短路故障诊断指标的必要条件。已知的故障指标包括电流谱分析、负序分量法和基于空间矢量的摆振法。本文将这三种方法应用于由PWM电压源逆变器供电的3.5 hp IPM电机获得的匝间短路故障实验数据。对结果进行了比较和分析,由于所提出的三种方法都不能明确地证明绕组短路故障的存在,因此从这个角度讨论了短路故障检测和缓解的实际困难。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnosis of stator short-circuit faults in an IPM synchronous machine using a space-vector pendulous oscillation method
Experimental characterization of interior permanent magnet (IPM) synchronous machines experiencing winding short-circuit faults is necessary in developing diagnostics indices to be used in detecting short-circuit winding faults. Known fault indices include the current spectrum analysis, the negative-sequence components method, and the space-vector based pendulous oscillation method. This paper applies all three methods to experimental turn-to-turn short-circuit fault data acquired from a 3.5 hp IPM motor energized by a PWM voltage source inverter. The results are compared and analyzed, and since none of the three methods presented unambiguously demonstrate the existence of a winding short-circuit fault, the practical difficulties of short-circuit fault detection and mitigation are discussed in that light.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信