设计具有温度传感器和脉搏传感器的柔性传感器手套,以帮助中风患者

Azriyenni Azhari Zakri, Arfianti Arfianti, A. Hamzah, M. Iqbal, Hamdy Madjid, Naufal Fikri Aulia
{"title":"设计具有温度传感器和脉搏传感器的柔性传感器手套,以帮助中风患者","authors":"Azriyenni Azhari Zakri, Arfianti Arfianti, A. Hamzah, M. Iqbal, Hamdy Madjid, Naufal Fikri Aulia","doi":"10.46338/ijetae1222_03","DOIUrl":null,"url":null,"abstract":"Stroke patients often have trouble in daily interactions, when the patient communicated with people who are guarding them. If the distance between the patient and their guard is far, this will make it difficult for the stroke patient to communicate. Therefore, this research designed a prototype glove with a flex sensor installed as a communication tool to aid stroke patients. The designed glove is paired with five flexible sensors to enable nurses easily to read the five-finger movement signals. This tool is also equipped with DS18B20 temperature and pulse sensors capable of monitoring the physical condition of stroke patients in real-time. Testing the flex sensor glove prototype was carried out by measuring temperature & heart rate through pulse and temperature sensors. The output data is in the form of text and sound displayed on the LCD and heard through the speaker through the DFPlayer mini module. The body temperature was measured using the DS18B20 temperature sensor and compared with an Avico digital thermometer which has an average error of 0.1%, indicating adequacy. The heart rate test results through the pulse sensor were compared with measurements obtained using measure heart rate correctly. Instant heart rate, which has an average error of 0.7%, hence, it can","PeriodicalId":169403,"journal":{"name":"International Journal of Emerging Technology and Advanced Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Designing Flex Sensor Gloves with Temperature Sensor & Pulse Sensor to Help Stroke Patients\",\"authors\":\"Azriyenni Azhari Zakri, Arfianti Arfianti, A. Hamzah, M. Iqbal, Hamdy Madjid, Naufal Fikri Aulia\",\"doi\":\"10.46338/ijetae1222_03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stroke patients often have trouble in daily interactions, when the patient communicated with people who are guarding them. If the distance between the patient and their guard is far, this will make it difficult for the stroke patient to communicate. Therefore, this research designed a prototype glove with a flex sensor installed as a communication tool to aid stroke patients. The designed glove is paired with five flexible sensors to enable nurses easily to read the five-finger movement signals. This tool is also equipped with DS18B20 temperature and pulse sensors capable of monitoring the physical condition of stroke patients in real-time. Testing the flex sensor glove prototype was carried out by measuring temperature & heart rate through pulse and temperature sensors. The output data is in the form of text and sound displayed on the LCD and heard through the speaker through the DFPlayer mini module. The body temperature was measured using the DS18B20 temperature sensor and compared with an Avico digital thermometer which has an average error of 0.1%, indicating adequacy. The heart rate test results through the pulse sensor were compared with measurements obtained using measure heart rate correctly. Instant heart rate, which has an average error of 0.7%, hence, it can\",\"PeriodicalId\":169403,\"journal\":{\"name\":\"International Journal of Emerging Technology and Advanced Engineering\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Emerging Technology and Advanced Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46338/ijetae1222_03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Emerging Technology and Advanced Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46338/ijetae1222_03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

中风患者在与看守他们的人交流时,往往在日常交往中遇到困难。如果病人和他们的警卫之间的距离很远,这将使中风病人难以沟通。因此,本研究设计了一种带有弯曲传感器的原型手套,作为帮助中风患者的沟通工具。设计的手套配有五个灵活的传感器,使护士能够轻松读取五指运动信号。该工具还配备了DS18B20温度和脉搏传感器,能够实时监测脑卒中患者的身体状况。通过脉冲和温度传感器测量温度和心率,对柔性传感器手套原型进行了测试。输出数据以文本和声音的形式显示在LCD上,并通过DFPlayer迷你模块通过扬声器听到。使用DS18B20温度传感器测量体温,并与Avico数字温度计进行比较,平均误差为0.1%,表明足够。将脉冲传感器测得的心率结果与正确测量心率得到的结果进行了比较。即时心率,平均误差为0.7%,因此,它可以
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Designing Flex Sensor Gloves with Temperature Sensor & Pulse Sensor to Help Stroke Patients
Stroke patients often have trouble in daily interactions, when the patient communicated with people who are guarding them. If the distance between the patient and their guard is far, this will make it difficult for the stroke patient to communicate. Therefore, this research designed a prototype glove with a flex sensor installed as a communication tool to aid stroke patients. The designed glove is paired with five flexible sensors to enable nurses easily to read the five-finger movement signals. This tool is also equipped with DS18B20 temperature and pulse sensors capable of monitoring the physical condition of stroke patients in real-time. Testing the flex sensor glove prototype was carried out by measuring temperature & heart rate through pulse and temperature sensors. The output data is in the form of text and sound displayed on the LCD and heard through the speaker through the DFPlayer mini module. The body temperature was measured using the DS18B20 temperature sensor and compared with an Avico digital thermometer which has an average error of 0.1%, indicating adequacy. The heart rate test results through the pulse sensor were compared with measurements obtained using measure heart rate correctly. Instant heart rate, which has an average error of 0.7%, hence, it can
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信