H. Tu, Bei Xu, Siyuan Chen, Xinyu Liang, Yuhua Du, S. Lukic
{"title":"弱电网中考虑电网阻抗和谐波的L滤波器并网逆变器控制","authors":"H. Tu, Bei Xu, Siyuan Chen, Xinyu Liang, Yuhua Du, S. Lukic","doi":"10.1109/IECON.2018.8591472","DOIUrl":null,"url":null,"abstract":"Inductor filter is widely used in grid-tied inverters. If an inverter with inductor filter operates in weak grid condition, voltage measurement error may exist due to the voltage sensor delay and the voltage drop on grid impedance. This can further lead to errors in the phase lock loop (PLL) and even system instability. In this paper, we analyze the voltage measurement error in weak grid condition in detail. All the essential elements in the measurement chain are considered. Analysis shows large DC offset and harmonic components may exist in the sampled voltage. To improve the PLL performance in weak grid condition, a PLL with extra DC offset and 2nd order harmonic rejection capability is presented. Further, the inverter current controller is designed considering grid impedance and grid harmonics. Experiments are performed to verify the presented method.","PeriodicalId":370319,"journal":{"name":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Control of Grid-Tied Inverter with L Filter in Weak Grid Considering Grid Impedance and Harmonics\",\"authors\":\"H. Tu, Bei Xu, Siyuan Chen, Xinyu Liang, Yuhua Du, S. Lukic\",\"doi\":\"10.1109/IECON.2018.8591472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inductor filter is widely used in grid-tied inverters. If an inverter with inductor filter operates in weak grid condition, voltage measurement error may exist due to the voltage sensor delay and the voltage drop on grid impedance. This can further lead to errors in the phase lock loop (PLL) and even system instability. In this paper, we analyze the voltage measurement error in weak grid condition in detail. All the essential elements in the measurement chain are considered. Analysis shows large DC offset and harmonic components may exist in the sampled voltage. To improve the PLL performance in weak grid condition, a PLL with extra DC offset and 2nd order harmonic rejection capability is presented. Further, the inverter current controller is designed considering grid impedance and grid harmonics. Experiments are performed to verify the presented method.\",\"PeriodicalId\":370319,\"journal\":{\"name\":\"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2018.8591472\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2018.8591472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Control of Grid-Tied Inverter with L Filter in Weak Grid Considering Grid Impedance and Harmonics
Inductor filter is widely used in grid-tied inverters. If an inverter with inductor filter operates in weak grid condition, voltage measurement error may exist due to the voltage sensor delay and the voltage drop on grid impedance. This can further lead to errors in the phase lock loop (PLL) and even system instability. In this paper, we analyze the voltage measurement error in weak grid condition in detail. All the essential elements in the measurement chain are considered. Analysis shows large DC offset and harmonic components may exist in the sampled voltage. To improve the PLL performance in weak grid condition, a PLL with extra DC offset and 2nd order harmonic rejection capability is presented. Further, the inverter current controller is designed considering grid impedance and grid harmonics. Experiments are performed to verify the presented method.