开关电源变换器的多采样平均电流控制

J. Calvente, H. Ramirez-Murillo, E. Vidal‐Idiarte, R. Giral, C. Restrepo
{"title":"开关电源变换器的多采样平均电流控制","authors":"J. Calvente, H. Ramirez-Murillo, E. Vidal‐Idiarte, R. Giral, C. Restrepo","doi":"10.1109/ICIT.2015.7125409","DOIUrl":null,"url":null,"abstract":"The digital current control method of switching converters studied in this work is based on taking more than one sample per switching period of the instantaneous current error waveform. To correctly regulate the average current value, as well as to simplify the system model, the controller must include a ripple filter. The proposed system includes a new low-phase-lag ripple filter. The whole system is first modelled in the s-domain to easily include the plant dynamics. The validity of the s-domain analysis up to half the switching frequency, once the controller is converted into the z-domain, has been verified by simulating its frequency response and its transient behavior. In comparison with other digital control methods, our approach provides a good general performance with a reasonable level of complexity.","PeriodicalId":156295,"journal":{"name":"2015 IEEE International Conference on Industrial Technology (ICIT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Multisampled average current control of switching power converters\",\"authors\":\"J. Calvente, H. Ramirez-Murillo, E. Vidal‐Idiarte, R. Giral, C. Restrepo\",\"doi\":\"10.1109/ICIT.2015.7125409\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The digital current control method of switching converters studied in this work is based on taking more than one sample per switching period of the instantaneous current error waveform. To correctly regulate the average current value, as well as to simplify the system model, the controller must include a ripple filter. The proposed system includes a new low-phase-lag ripple filter. The whole system is first modelled in the s-domain to easily include the plant dynamics. The validity of the s-domain analysis up to half the switching frequency, once the controller is converted into the z-domain, has been verified by simulating its frequency response and its transient behavior. In comparison with other digital control methods, our approach provides a good general performance with a reasonable level of complexity.\",\"PeriodicalId\":156295,\"journal\":{\"name\":\"2015 IEEE International Conference on Industrial Technology (ICIT)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Conference on Industrial Technology (ICIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2015.7125409\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Industrial Technology (ICIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2015.7125409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文研究的开关变换器的数字电流控制方法是基于每个开关周期对瞬时电流误差波形进行多个采样。为了正确地调节平均电流值,以及简化系统模型,控制器必须包含纹波滤波器。该系统包括一个新的低相位滞后纹波滤波器。整个系统首先在s域建模,以便于包含植物动力学。一旦控制器转换为z域,s域分析的有效性可达开关频率的一半,通过模拟其频率响应和瞬态行为来验证。与其他数字控制方法相比,我们的方法在合理的复杂程度下提供了良好的综合性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multisampled average current control of switching power converters
The digital current control method of switching converters studied in this work is based on taking more than one sample per switching period of the instantaneous current error waveform. To correctly regulate the average current value, as well as to simplify the system model, the controller must include a ripple filter. The proposed system includes a new low-phase-lag ripple filter. The whole system is first modelled in the s-domain to easily include the plant dynamics. The validity of the s-domain analysis up to half the switching frequency, once the controller is converted into the z-domain, has been verified by simulating its frequency response and its transient behavior. In comparison with other digital control methods, our approach provides a good general performance with a reasonable level of complexity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信