利用电压稳定指标防止电压不稳定时继电器误动作

Ahmad Farid Bin Abidin, A. Mohamed
{"title":"利用电压稳定指标防止电压不稳定时继电器误动作","authors":"Ahmad Farid Bin Abidin, A. Mohamed","doi":"10.1109/EEEIC.2010.5489947","DOIUrl":null,"url":null,"abstract":"Distance relays may operate undesirably not because of faults but because of overloads and its operations have contributed to voltage collapses worldwide. To overcome this problem, the voltage stability index (VSI) is used as a criteria to differentiate between faults and voltage collapse. The VSI is developed based on the change of apparent power and it uses some local information such as bus voltage magnitude and load current magnitude. To evaluate the effectiveness of the VSI, fault and the proximity voltage collapse simulations were carried out on the IEEE 9 bus system. Results proved that the VSI is better than the SSI in terms of differentiating between a fault and a voltage instability condition. Therefore, the VSI can be applied in adaptive distance protection relaying for discriminating between a fault and a voltage collapse so as to prevent undesirable zone 3 distance relay operations.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"On the use of voltage stability index to prevent undesirable distance relay operation during voltage instability\",\"authors\":\"Ahmad Farid Bin Abidin, A. Mohamed\",\"doi\":\"10.1109/EEEIC.2010.5489947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distance relays may operate undesirably not because of faults but because of overloads and its operations have contributed to voltage collapses worldwide. To overcome this problem, the voltage stability index (VSI) is used as a criteria to differentiate between faults and voltage collapse. The VSI is developed based on the change of apparent power and it uses some local information such as bus voltage magnitude and load current magnitude. To evaluate the effectiveness of the VSI, fault and the proximity voltage collapse simulations were carried out on the IEEE 9 bus system. Results proved that the VSI is better than the SSI in terms of differentiating between a fault and a voltage instability condition. Therefore, the VSI can be applied in adaptive distance protection relaying for discriminating between a fault and a voltage collapse so as to prevent undesirable zone 3 distance relay operations.\",\"PeriodicalId\":197298,\"journal\":{\"name\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2010.5489947\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5489947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

距离继电器可能不受欢迎地运行,不是因为故障,而是因为过载,它的运行导致了世界范围内的电压崩溃。为了克服这一问题,将电压稳定指数(VSI)作为区分故障和电压崩溃的标准。VSI是基于视在功率的变化而开发的,它利用了母线电压幅值和负载电流幅值等局部信息。为了评估VSI的有效性,在ieee9总线系统上进行了故障和邻近电压崩溃仿真。结果表明,在区分故障和电压不稳定情况方面,VSI优于SSI。因此,VSI可以应用于自适应距离保护继电器中,用于区分故障和电压崩溃,从而防止不良的3区距离继电器操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the use of voltage stability index to prevent undesirable distance relay operation during voltage instability
Distance relays may operate undesirably not because of faults but because of overloads and its operations have contributed to voltage collapses worldwide. To overcome this problem, the voltage stability index (VSI) is used as a criteria to differentiate between faults and voltage collapse. The VSI is developed based on the change of apparent power and it uses some local information such as bus voltage magnitude and load current magnitude. To evaluate the effectiveness of the VSI, fault and the proximity voltage collapse simulations were carried out on the IEEE 9 bus system. Results proved that the VSI is better than the SSI in terms of differentiating between a fault and a voltage instability condition. Therefore, the VSI can be applied in adaptive distance protection relaying for discriminating between a fault and a voltage collapse so as to prevent undesirable zone 3 distance relay operations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信