{"title":"空调动力学对电力系统暂态稳定极限影响的量化","authors":"Benjamin P. Wiseman, Le Xie","doi":"10.1109/TPEC.2019.8662191","DOIUrl":null,"url":null,"abstract":"Dynamic load characteristics are becoming an increasingly important consideration for power systems with a large penetration of residential air conditioning. Residential air conditioner stalling in response to faults plays a large role in Fault-Induced Delayed Voltage Recovery events. To further study this connection, this work seeks to tie load parameter variations directly to changes in assessed transient stability limits. This connection is first considered at an area-wide level, before a bus-level locational sensitivity metric is introduced. Test results allow for validation of common assumptions about the effects of air conditioner motor stalling, as well as identification of which busses are most critical to the system response near a stability limit.","PeriodicalId":424038,"journal":{"name":"2019 IEEE Texas Power and Energy Conference (TPEC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantifying the Effect of Air Conditioning Dynamics on Power System Transient Stability Limits\",\"authors\":\"Benjamin P. Wiseman, Le Xie\",\"doi\":\"10.1109/TPEC.2019.8662191\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dynamic load characteristics are becoming an increasingly important consideration for power systems with a large penetration of residential air conditioning. Residential air conditioner stalling in response to faults plays a large role in Fault-Induced Delayed Voltage Recovery events. To further study this connection, this work seeks to tie load parameter variations directly to changes in assessed transient stability limits. This connection is first considered at an area-wide level, before a bus-level locational sensitivity metric is introduced. Test results allow for validation of common assumptions about the effects of air conditioner motor stalling, as well as identification of which busses are most critical to the system response near a stability limit.\",\"PeriodicalId\":424038,\"journal\":{\"name\":\"2019 IEEE Texas Power and Energy Conference (TPEC)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Texas Power and Energy Conference (TPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TPEC.2019.8662191\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Texas Power and Energy Conference (TPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TPEC.2019.8662191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Quantifying the Effect of Air Conditioning Dynamics on Power System Transient Stability Limits
Dynamic load characteristics are becoming an increasingly important consideration for power systems with a large penetration of residential air conditioning. Residential air conditioner stalling in response to faults plays a large role in Fault-Induced Delayed Voltage Recovery events. To further study this connection, this work seeks to tie load parameter variations directly to changes in assessed transient stability limits. This connection is first considered at an area-wide level, before a bus-level locational sensitivity metric is introduced. Test results allow for validation of common assumptions about the effects of air conditioner motor stalling, as well as identification of which busses are most critical to the system response near a stability limit.