在不正确信息下计算0.4 Kv馈线的功率损耗,创新了几代负载电流动态管理模型

J. V. Shitikova, S. Shelyug
{"title":"在不正确信息下计算0.4 Kv馈线的功率损耗,创新了几代负载电流动态管理模型","authors":"J. V. Shitikova, S. Shelyug","doi":"10.1109/SCM.2017.7970537","DOIUrl":null,"url":null,"abstract":"The non sinusoidal currents, which is caused by the increase in the percentage of electric energy consumers with nonlinear volt-ampere characteristic, has an increasing influence on the amount of losses. The different currents amplitude and the degree of distortion in phases are also the significant factors. Existing methods for calculating power losses either take into account only the Effective current values(the generally accepted practice in Russia) or take into account the sinusoidal distortion of the shape of the current curve (IEEE Std1459-2010, IEEE Std 519–2014). In this paper, the cases of incorrect description of the load current are described and the effect of distortion of the curve's shape of the flowing current on the amount of power losses in a three-phase four-wire transmission line with a voltage of 0.4 kV is investigated. It is shown that the amount of electric power losses at an incorrectly specified load can exceed the amount of electric power losses of a sinusoidal case by several times.","PeriodicalId":315574,"journal":{"name":"2017 XX IEEE International Conference on Soft Computing and Measurements (SCM)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calculation of power losses in feeders 0,4 Kv with incorrect information about the load current dynamic management model of innovations generations\",\"authors\":\"J. V. Shitikova, S. Shelyug\",\"doi\":\"10.1109/SCM.2017.7970537\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The non sinusoidal currents, which is caused by the increase in the percentage of electric energy consumers with nonlinear volt-ampere characteristic, has an increasing influence on the amount of losses. The different currents amplitude and the degree of distortion in phases are also the significant factors. Existing methods for calculating power losses either take into account only the Effective current values(the generally accepted practice in Russia) or take into account the sinusoidal distortion of the shape of the current curve (IEEE Std1459-2010, IEEE Std 519–2014). In this paper, the cases of incorrect description of the load current are described and the effect of distortion of the curve's shape of the flowing current on the amount of power losses in a three-phase four-wire transmission line with a voltage of 0.4 kV is investigated. It is shown that the amount of electric power losses at an incorrectly specified load can exceed the amount of electric power losses of a sinusoidal case by several times.\",\"PeriodicalId\":315574,\"journal\":{\"name\":\"2017 XX IEEE International Conference on Soft Computing and Measurements (SCM)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 XX IEEE International Conference on Soft Computing and Measurements (SCM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCM.2017.7970537\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 XX IEEE International Conference on Soft Computing and Measurements (SCM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCM.2017.7970537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于具有非线性伏安特性的电能消费者所占比例的增加而引起的非正弦电流对损耗量的影响越来越大。不同的电流幅值和相位畸变程度也是重要的影响因素。现有的计算功率损耗的方法要么只考虑有效电流值(俄罗斯普遍接受的做法),要么考虑电流曲线形状的正弦畸变(IEEE标准1459-2010,IEEE标准519-2014)。本文介绍了在电压为0.4 kV的三相四线输电线路中,负荷电流描述不正确的情况,并研究了电流曲线形状的畸变对损耗量的影响。结果表明,在不正确指定的负载下,功率损失量可能超过正弦波情况下的功率损失量数倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calculation of power losses in feeders 0,4 Kv with incorrect information about the load current dynamic management model of innovations generations
The non sinusoidal currents, which is caused by the increase in the percentage of electric energy consumers with nonlinear volt-ampere characteristic, has an increasing influence on the amount of losses. The different currents amplitude and the degree of distortion in phases are also the significant factors. Existing methods for calculating power losses either take into account only the Effective current values(the generally accepted practice in Russia) or take into account the sinusoidal distortion of the shape of the current curve (IEEE Std1459-2010, IEEE Std 519–2014). In this paper, the cases of incorrect description of the load current are described and the effect of distortion of the curve's shape of the flowing current on the amount of power losses in a three-phase four-wire transmission line with a voltage of 0.4 kV is investigated. It is shown that the amount of electric power losses at an incorrectly specified load can exceed the amount of electric power losses of a sinusoidal case by several times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信