18脉冲整流器用于谐波缓解

S. Kocman, V. Kolář, T. Trung Vo
{"title":"18脉冲整流器用于谐波缓解","authors":"S. Kocman, V. Kolář, T. Trung Vo","doi":"10.1109/ICHQP.2010.5625409","DOIUrl":null,"url":null,"abstract":"Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Eighteen-pulse rectifiers for harmonic mitigation\",\"authors\":\"S. Kocman, V. Kolář, T. Trung Vo\",\"doi\":\"10.1109/ICHQP.2010.5625409\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.\",\"PeriodicalId\":180078,\"journal\":{\"name\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2010.5625409\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

多脉冲整流器是交流调速传动中谐波抑制的技术解决方案之一。12脉冲,18脉冲和24脉冲整流器拓扑结构用于各种技术应用。本文介绍了18脉冲整流器的两种拓扑结构:Dy1z1+200z1−200和Dd0diii0+200diii0−200变压器的实验测量和仿真结果。为了模拟这两种18脉冲整流器在不同电压畸变水平下的行为,在EMTP-ATP仿真程序中编写了用FORTRAN编写的程序。实验测量和仿真结果均证明了该方法具有较高的谐波抑制效果。本文还比较了十八脉冲整流器与其他谐波抑制技术的优缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Eighteen-pulse rectifiers for harmonic mitigation
Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信