{"title":"风力涡轮机工业电网的闪烁测量","authors":"Y. Hsu, C. Lu","doi":"10.1109/PES.2006.1709054","DOIUrl":null,"url":null,"abstract":"The power fluctuations from the wind turbines during switching or continuous operation cause voltage fluctuation on the system connected. Statistical analysis results of voltage quality data recorded at an industrial site equipped with two doubly fed induction generators (DFIG) are presented in this paper. Flicker issue during higher power output period is investigated. Flicker propagations in the upstream and downstream directions are studied. This paper also provide statistical analysis results of the relation between two short term flicker severity indices Pst and DeltaV10 recorded by two different power quality meters","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Flicker measurements at an industrial power network with wind turbines\",\"authors\":\"Y. Hsu, C. Lu\",\"doi\":\"10.1109/PES.2006.1709054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The power fluctuations from the wind turbines during switching or continuous operation cause voltage fluctuation on the system connected. Statistical analysis results of voltage quality data recorded at an industrial site equipped with two doubly fed induction generators (DFIG) are presented in this paper. Flicker issue during higher power output period is investigated. Flicker propagations in the upstream and downstream directions are studied. This paper also provide statistical analysis results of the relation between two short term flicker severity indices Pst and DeltaV10 recorded by two different power quality meters\",\"PeriodicalId\":267582,\"journal\":{\"name\":\"2006 IEEE Power Engineering Society General Meeting\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2006.1709054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Flicker measurements at an industrial power network with wind turbines
The power fluctuations from the wind turbines during switching or continuous operation cause voltage fluctuation on the system connected. Statistical analysis results of voltage quality data recorded at an industrial site equipped with two doubly fed induction generators (DFIG) are presented in this paper. Flicker issue during higher power output period is investigated. Flicker propagations in the upstream and downstream directions are studied. This paper also provide statistical analysis results of the relation between two short term flicker severity indices Pst and DeltaV10 recorded by two different power quality meters