{"title":"基于dsp的三相交/直流PWM变换器电流控制与模型参考自适应辨识","authors":"T. Takeshita, N. Matsui","doi":"10.1109/PESC.1992.254840","DOIUrl":null,"url":null,"abstract":"The authors report the input current control of a three-phase pulse-width-modulated (PWM) converter. The proposed control can realize a unity effective input power factor and a sinusoidal input current waveform. The current control is performed with the instantaneous voltage equation of the converter, and system parameters are identified by a model reference adaptive systems (MRAS). Therefore, high-performance current control is achieved even if the converter parameters are unknown. In the parameter identification, the number of identified parameters can be halved to reduce the convergence time by expanding a conventional MRAS to the complex plane and by shifting the sampling points of the identification from those of the current control. The effectiveness of the current control and parameter identification methods has been demonstrated by simulations and experiments.<<ETX>>","PeriodicalId":402706,"journal":{"name":"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"DSP-based current control of three-phase AC/DC PWM converter with model reference adaptive identifier\",\"authors\":\"T. Takeshita, N. Matsui\",\"doi\":\"10.1109/PESC.1992.254840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors report the input current control of a three-phase pulse-width-modulated (PWM) converter. The proposed control can realize a unity effective input power factor and a sinusoidal input current waveform. The current control is performed with the instantaneous voltage equation of the converter, and system parameters are identified by a model reference adaptive systems (MRAS). Therefore, high-performance current control is achieved even if the converter parameters are unknown. In the parameter identification, the number of identified parameters can be halved to reduce the convergence time by expanding a conventional MRAS to the complex plane and by shifting the sampling points of the identification from those of the current control. The effectiveness of the current control and parameter identification methods has been demonstrated by simulations and experiments.<<ETX>>\",\"PeriodicalId\":402706,\"journal\":{\"name\":\"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-06-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1992.254840\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '92 Record. 23rd Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1992.254840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文报道了一种三相脉宽调制(PWM)变换器的输入电流控制。该控制可以实现统一的有效输入功率因数和正弦输入电流波形。利用变换器的瞬时电压方程进行电流控制,采用模型参考自适应系统(MRAS)识别系统参数。因此,即使变换器参数未知,也可以实现高性能的电流控制。在参数识别中,通过将传统的MRAS扩展到复杂平面,并将识别的采样点从当前控制的采样点移开,可以将识别的参数数量减半以缩短收敛时间。仿真和实验验证了电流控制和参数辨识方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DSP-based current control of three-phase AC/DC PWM converter with model reference adaptive identifier
The authors report the input current control of a three-phase pulse-width-modulated (PWM) converter. The proposed control can realize a unity effective input power factor and a sinusoidal input current waveform. The current control is performed with the instantaneous voltage equation of the converter, and system parameters are identified by a model reference adaptive systems (MRAS). Therefore, high-performance current control is achieved even if the converter parameters are unknown. In the parameter identification, the number of identified parameters can be halved to reduce the convergence time by expanding a conventional MRAS to the complex plane and by shifting the sampling points of the identification from those of the current control. The effectiveness of the current control and parameter identification methods has been demonstrated by simulations and experiments.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信