{"title":"三相四脚并联有源电力滤波器补偿谐波和无功功率","authors":"I. I. Abdalla, K. S. R. Rao, N. Perumal","doi":"10.1109/ISCI.2011.5958965","DOIUrl":null,"url":null,"abstract":"This paper presents a compensating system for the harmonics and the reactive power using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network and aims to minimize the harmonics and neutral current. Two control approaches p-q theory based hysteresis current control and load current detection based hysteresis current control are proposed. To validate the compensation performance of SAPF a distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results are presented to assess the performance of SAPF to minimize the total harmonics distortion (THD) and neutral current, as well as to compensate the reactive power.","PeriodicalId":166647,"journal":{"name":"2011 IEEE Symposium on Computers & Informatics","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Three-phase four-leg shunt active power filter to compensate harmonics and reactive power\",\"authors\":\"I. I. Abdalla, K. S. R. Rao, N. Perumal\",\"doi\":\"10.1109/ISCI.2011.5958965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a compensating system for the harmonics and the reactive power using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network and aims to minimize the harmonics and neutral current. Two control approaches p-q theory based hysteresis current control and load current detection based hysteresis current control are proposed. To validate the compensation performance of SAPF a distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results are presented to assess the performance of SAPF to minimize the total harmonics distortion (THD) and neutral current, as well as to compensate the reactive power.\",\"PeriodicalId\":166647,\"journal\":{\"name\":\"2011 IEEE Symposium on Computers & Informatics\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Symposium on Computers & Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISCI.2011.5958965\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Symposium on Computers & Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCI.2011.5958965","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Three-phase four-leg shunt active power filter to compensate harmonics and reactive power
This paper presents a compensating system for the harmonics and the reactive power using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network and aims to minimize the harmonics and neutral current. Two control approaches p-q theory based hysteresis current control and load current detection based hysteresis current control are proposed. To validate the compensation performance of SAPF a distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results are presented to assess the performance of SAPF to minimize the total harmonics distortion (THD) and neutral current, as well as to compensate the reactive power.