无慢化剂中子探测

R. Hansen, A. J. Peurrung, P. Reeder, D.C. Stromswold
{"title":"无慢化剂中子探测","authors":"R. Hansen, A. J. Peurrung, P. Reeder, D.C. Stromswold","doi":"10.1109/NSSMIC.1998.775161","DOIUrl":null,"url":null,"abstract":"Recent investigations have indicated that moderator-free thermal neutron detection may hold advantages for applications such as long-range neutron source detection and remote-handled TRU waste characterization. Moderator-free neutron detection involves the use of a directionally shielded thermal neutron detector to record only those thermal neutrons incident from a particular direction. Minimization of the amount of moderating material at the location of the detector avoids the detection of fast neutrons, which constitute a substantial fraction of background neutrons. Experimental results reported in this paper were generated using a square meter instrument constructed at Pacific Northwest National Laboratory (PNNL). Such an approach to neutron detection should allow the reasonably rapid detection of modest neutron sources from distances greater than 50 meters and the partial characterization of waste with contact dose rates as high as 10,000 R/hr.","PeriodicalId":129202,"journal":{"name":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Moderator-free neutron detection\",\"authors\":\"R. Hansen, A. J. Peurrung, P. Reeder, D.C. Stromswold\",\"doi\":\"10.1109/NSSMIC.1998.775161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recent investigations have indicated that moderator-free thermal neutron detection may hold advantages for applications such as long-range neutron source detection and remote-handled TRU waste characterization. Moderator-free neutron detection involves the use of a directionally shielded thermal neutron detector to record only those thermal neutrons incident from a particular direction. Minimization of the amount of moderating material at the location of the detector avoids the detection of fast neutrons, which constitute a substantial fraction of background neutrons. Experimental results reported in this paper were generated using a square meter instrument constructed at Pacific Northwest National Laboratory (PNNL). Such an approach to neutron detection should allow the reasonably rapid detection of modest neutron sources from distances greater than 50 meters and the partial characterization of waste with contact dose rates as high as 10,000 R/hr.\",\"PeriodicalId\":129202,\"journal\":{\"name\":\"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1998.775161\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1998.775161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

最近的研究表明,无慢化剂热中子探测可能在远程中子源探测和远程处理TRU废物表征等应用中具有优势。无慢化剂中子探测包括使用定向屏蔽热中子探测器,只记录从特定方向入射的热中子。在探测器的位置上,将慢化材料的量最小化,避免了快中子的检测,而快中子构成了背景中子的很大一部分。本文的实验结果是在太平洋西北国家实验室(PNNL)建造的一个平方米的仪器上产生的。这种中子探测方法应允许在距离大于50米的地方合理快速地探测中等中子源,并对接触剂量率高达10,000 R/hr的废物进行部分表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Moderator-free neutron detection
Recent investigations have indicated that moderator-free thermal neutron detection may hold advantages for applications such as long-range neutron source detection and remote-handled TRU waste characterization. Moderator-free neutron detection involves the use of a directionally shielded thermal neutron detector to record only those thermal neutrons incident from a particular direction. Minimization of the amount of moderating material at the location of the detector avoids the detection of fast neutrons, which constitute a substantial fraction of background neutrons. Experimental results reported in this paper were generated using a square meter instrument constructed at Pacific Northwest National Laboratory (PNNL). Such an approach to neutron detection should allow the reasonably rapid detection of modest neutron sources from distances greater than 50 meters and the partial characterization of waste with contact dose rates as high as 10,000 R/hr.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信