使用时空光学相干断层扫描(stock -t)系统进行超快体积成像,直接从结构数据监测小鼠视网膜血管的血流动力学

Wiktor M. Kulesza, M. Wielgo, P. Węgrzyn, S. Tomczewski, O. Çetinkaya, Katarzyna Kordecka, Anna Galińska, Bartłomiej Bałamut, E. Auksorius, A. Foik, R. Zawadzki, M. Wojtkowski, D. Borycki, A. Curatolo
{"title":"使用时空光学相干断层扫描(stock -t)系统进行超快体积成像,直接从结构数据监测小鼠视网膜血管的血流动力学","authors":"Wiktor M. Kulesza, M. Wielgo, P. Węgrzyn, S. Tomczewski, O. Çetinkaya, Katarzyna Kordecka, Anna Galińska, Bartłomiej Bałamut, E. Auksorius, A. Foik, R. Zawadzki, M. Wojtkowski, D. Borycki, A. Curatolo","doi":"10.1117/12.2670568","DOIUrl":null,"url":null,"abstract":"We present a novel ultrafast imaging system using Spatio-Temporal Optical Coherence Tomography (STOC-T), capable of acquiring structural images of a mouse retina at a volumetric rate of 112 Hz. A calibrated fundus camera and white-light illumination aid the alignment of the mouse and the adjustment of the focal plane in the mouse retina for the STOC-T image. We extract pulsatile blood flow frequency and other hemodynamic parameters from multiple retinal and choroidal vessels from structural-only OCT images, highlighting the prospects of STOC-T for monitoring retinal hemodynamics in a simple way.","PeriodicalId":278089,"journal":{"name":"European Conference on Biomedical Optics","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrafast volumetric imaging with a spatio-temporal optical coherence tomography (STOC-T) system for monitoring hemodynamics in mouse retinal vessels directly from structural data\",\"authors\":\"Wiktor M. Kulesza, M. Wielgo, P. Węgrzyn, S. Tomczewski, O. Çetinkaya, Katarzyna Kordecka, Anna Galińska, Bartłomiej Bałamut, E. Auksorius, A. Foik, R. Zawadzki, M. Wojtkowski, D. Borycki, A. Curatolo\",\"doi\":\"10.1117/12.2670568\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a novel ultrafast imaging system using Spatio-Temporal Optical Coherence Tomography (STOC-T), capable of acquiring structural images of a mouse retina at a volumetric rate of 112 Hz. A calibrated fundus camera and white-light illumination aid the alignment of the mouse and the adjustment of the focal plane in the mouse retina for the STOC-T image. We extract pulsatile blood flow frequency and other hemodynamic parameters from multiple retinal and choroidal vessels from structural-only OCT images, highlighting the prospects of STOC-T for monitoring retinal hemodynamics in a simple way.\",\"PeriodicalId\":278089,\"journal\":{\"name\":\"European Conference on Biomedical Optics\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Conference on Biomedical Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2670568\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Conference on Biomedical Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2670568","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们提出了一种使用时空光学相干断层扫描(stock - t)的新型超快成像系统,能够以112 Hz的体积速率获取小鼠视网膜的结构图像。校准后的眼底相机和白光照明有助于小鼠视网膜的对齐和焦平面的调整,以获得stock - t图像。我们从仅结构OCT图像中提取多视网膜和脉络膜血管的脉动血流频率和其他血流动力学参数,突出了sto - t用于简单监测视网膜血流动力学的前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ultrafast volumetric imaging with a spatio-temporal optical coherence tomography (STOC-T) system for monitoring hemodynamics in mouse retinal vessels directly from structural data
We present a novel ultrafast imaging system using Spatio-Temporal Optical Coherence Tomography (STOC-T), capable of acquiring structural images of a mouse retina at a volumetric rate of 112 Hz. A calibrated fundus camera and white-light illumination aid the alignment of the mouse and the adjustment of the focal plane in the mouse retina for the STOC-T image. We extract pulsatile blood flow frequency and other hemodynamic parameters from multiple retinal and choroidal vessels from structural-only OCT images, highlighting the prospects of STOC-T for monitoring retinal hemodynamics in a simple way.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信