一种不需要外部偏置电源的浮栅MOSFET剂量计

N. G. Tarr, G. Mackay, K. Shortt, I. Thomson
{"title":"一种不需要外部偏置电源的浮栅MOSFET剂量计","authors":"N. G. Tarr, G. Mackay, K. Shortt, I. Thomson","doi":"10.1109/RADECS.1997.698909","DOIUrl":null,"url":null,"abstract":"MOSFET dosimeters incorporating an electrically floating polysilicon gate have been fabricated in a commercial CMOS technology. Charge is placed on the floating gate by tunnelling from a small overlapping injector gate. Subsequent irradiation partially discharges the floating gate, producing a change in threshold voltage which can be used to infer the absorbed dose. No external power source is required during this sensing period. Sensitivities up to 70 mV Gy/sup -1/ (0.7 mV/rad) have been obtained for temperature-compensated matched-pair dosimeters under /sup 60/Co gamma irradiation.","PeriodicalId":106774,"journal":{"name":"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"70","resultStr":"{\"title\":\"A floating gate MOSFET dosimeter requiring no external bias supply\",\"authors\":\"N. G. Tarr, G. Mackay, K. Shortt, I. Thomson\",\"doi\":\"10.1109/RADECS.1997.698909\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"MOSFET dosimeters incorporating an electrically floating polysilicon gate have been fabricated in a commercial CMOS technology. Charge is placed on the floating gate by tunnelling from a small overlapping injector gate. Subsequent irradiation partially discharges the floating gate, producing a change in threshold voltage which can be used to infer the absorbed dose. No external power source is required during this sensing period. Sensitivities up to 70 mV Gy/sup -1/ (0.7 mV/rad) have been obtained for temperature-compensated matched-pair dosimeters under /sup 60/Co gamma irradiation.\",\"PeriodicalId\":106774,\"journal\":{\"name\":\"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"70\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RADECS.1997.698909\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.1997.698909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 70

摘要

结合电浮动多晶硅栅极的MOSFET剂量计已经在商用CMOS技术中制造出来。通过从一个小的重叠喷油器喷口穿隧将电荷放置在浮栅上。随后的辐照使浮栅部分放电,产生阈值电压的变化,可用于推断吸收剂量。在此传感期间不需要外部电源。在/sup 60/Co辐照下,温度补偿匹配对剂量计的灵敏度可达70 mV Gy/sup -1/ (0.7 mV/rad)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A floating gate MOSFET dosimeter requiring no external bias supply
MOSFET dosimeters incorporating an electrically floating polysilicon gate have been fabricated in a commercial CMOS technology. Charge is placed on the floating gate by tunnelling from a small overlapping injector gate. Subsequent irradiation partially discharges the floating gate, producing a change in threshold voltage which can be used to infer the absorbed dose. No external power source is required during this sensing period. Sensitivities up to 70 mV Gy/sup -1/ (0.7 mV/rad) have been obtained for temperature-compensated matched-pair dosimeters under /sup 60/Co gamma irradiation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信