{"title":"粪便钙保护蛋白的异质性反映了肠道中性粒细胞胞外陷阱(NETs)的产生:新的免疫测定方法可用","authors":"M. Fagerhol, J. Rugtveit","doi":"10.3390/jmp3010004","DOIUrl":null,"url":null,"abstract":"Background: We aimed at obtaining more information on the structure of fecal calprotectin (CP) as a basis for establishing improved quantitative assays and detection of Neutrophil Extracellular Traps (NETs) in stools. Commercial fecal CP assays produce different results, probably due to differences in antibodies, extraction procedures, and standards used. In addition, the structure of fecal CP may be different from that in the standard so that rules for immunoassays are violated. We aimed at solving these problems by studying the structure of fecal CP and developing new antibodies and assay procedures including some for NETs in stools. Methods and Findings: Stool samples from children with abdominal symptoms were extracted by a conventional and a new procedure. Some extracts were run on anion exchange and size exclusion chromatography, and fractions were tested on ELISAs by use of ten new mouse monoclonal antibodies against the CP subunit S100A9. Hybrid ELISAs (named HELISA) were established using anti-DNA or anti-histones for coating of microwells, and enzyme labelled anti-CP was used for development. By ion exchange chromatography, five to ten fecal CP subfraction peaks differing in net electric charge were found, all of which contained the major chromatin components. The presence of DNA and histones followed calprotectin in the chromatographic fractions suggesting that NETs are generated in the gut lumen. The new CP monoclonals reacted very differently against the subfractions so that a mixture of them (called MiMo) must be used to obtain reliable assay values for fecal CP. A new method called FELISA was developed where standards and samples are applied directly in Nunc (Denmark) MaxiSorp plates, without any catching antibody. It takes advantage of the property of CP to bind strongly to the plastic in wells. This method has a higher sensitivity because it will detect CP molecules with only one antigenic epitope available. It will give more reliable estimates and more efficient selection of patients for complex diagnostic procedures. We also developed an alternative to the FELISA: a competitive ELISA where S100A9 coated in microwells will compete with CP in standards and samples for binding to a properly diluted HRP-anti-CP solution. In this method, the presence of other proteins in extraction or dilution buffers will not interfere. Using the HELISA, about 65% of the patients had detectable fecal NETs in concentrations between 150 and 1500 ng/mL; however, the values correlated poorly with CP values. Extraction of fecal samples with a simple buffer of TBS, and pH 5 with 5 mM EDTA, gave a yield of about 90%, while the yields of commercial kits are not specified or lie around 50%. A fecal CP standard will bring methods in accordance with the requirements for immunoassays that the structure of CP in the standard and sample must be the same. A mixture of fecal anion exchange fractions as a standard may be a solution to this problem. The principle worked in the first trial by giving the same values after storage of such a standard at 5C for four months. Conclusions: Fecal CP consists of at least five subfractions containing NETs or degradation products thereof. Commercial kits should not be accepted for clinical use unless it has been shown that they can detect all subfractions which may require the use of a mixture of monoclonals. The methods presented here can be used for such a quality control. The HELISA methods can be used for assays on NETs in stools and to study their possible pathogenic effects in the gut. Use of the FELISA and the S100A9 competitive method may give increased sensitivity, higher precision, and better selection of patients for more complex procedures.","PeriodicalId":124426,"journal":{"name":"Journal of Molecular Pathology","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Heterogeneity of Fecal Calprotectin Reflecting Generation of Neutrophil Extracellular Traps (NETs) in the Gut: New Immunoassays Are Available\",\"authors\":\"M. Fagerhol, J. Rugtveit\",\"doi\":\"10.3390/jmp3010004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: We aimed at obtaining more information on the structure of fecal calprotectin (CP) as a basis for establishing improved quantitative assays and detection of Neutrophil Extracellular Traps (NETs) in stools. Commercial fecal CP assays produce different results, probably due to differences in antibodies, extraction procedures, and standards used. In addition, the structure of fecal CP may be different from that in the standard so that rules for immunoassays are violated. We aimed at solving these problems by studying the structure of fecal CP and developing new antibodies and assay procedures including some for NETs in stools. Methods and Findings: Stool samples from children with abdominal symptoms were extracted by a conventional and a new procedure. Some extracts were run on anion exchange and size exclusion chromatography, and fractions were tested on ELISAs by use of ten new mouse monoclonal antibodies against the CP subunit S100A9. Hybrid ELISAs (named HELISA) were established using anti-DNA or anti-histones for coating of microwells, and enzyme labelled anti-CP was used for development. By ion exchange chromatography, five to ten fecal CP subfraction peaks differing in net electric charge were found, all of which contained the major chromatin components. The presence of DNA and histones followed calprotectin in the chromatographic fractions suggesting that NETs are generated in the gut lumen. The new CP monoclonals reacted very differently against the subfractions so that a mixture of them (called MiMo) must be used to obtain reliable assay values for fecal CP. A new method called FELISA was developed where standards and samples are applied directly in Nunc (Denmark) MaxiSorp plates, without any catching antibody. It takes advantage of the property of CP to bind strongly to the plastic in wells. This method has a higher sensitivity because it will detect CP molecules with only one antigenic epitope available. It will give more reliable estimates and more efficient selection of patients for complex diagnostic procedures. We also developed an alternative to the FELISA: a competitive ELISA where S100A9 coated in microwells will compete with CP in standards and samples for binding to a properly diluted HRP-anti-CP solution. In this method, the presence of other proteins in extraction or dilution buffers will not interfere. Using the HELISA, about 65% of the patients had detectable fecal NETs in concentrations between 150 and 1500 ng/mL; however, the values correlated poorly with CP values. Extraction of fecal samples with a simple buffer of TBS, and pH 5 with 5 mM EDTA, gave a yield of about 90%, while the yields of commercial kits are not specified or lie around 50%. A fecal CP standard will bring methods in accordance with the requirements for immunoassays that the structure of CP in the standard and sample must be the same. A mixture of fecal anion exchange fractions as a standard may be a solution to this problem. The principle worked in the first trial by giving the same values after storage of such a standard at 5C for four months. Conclusions: Fecal CP consists of at least five subfractions containing NETs or degradation products thereof. Commercial kits should not be accepted for clinical use unless it has been shown that they can detect all subfractions which may require the use of a mixture of monoclonals. The methods presented here can be used for such a quality control. The HELISA methods can be used for assays on NETs in stools and to study their possible pathogenic effects in the gut. Use of the FELISA and the S100A9 competitive method may give increased sensitivity, higher precision, and better selection of patients for more complex procedures.\",\"PeriodicalId\":124426,\"journal\":{\"name\":\"Journal of Molecular Pathology\",\"volume\":\"81 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Molecular Pathology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/jmp3010004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Molecular Pathology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jmp3010004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
摘要
背景:我们旨在获得更多关于粪便钙保护蛋白(CP)结构的信息,作为建立改进的定量分析和检测粪便中性粒细胞胞外陷阱(NETs)的基础。商业粪便CP测定产生不同的结果,可能是由于抗体、提取程序和所用标准的不同。此外,粪便CP的结构可能与标准中的结构不同,从而违反了免疫测定规则。我们的目标是通过研究粪便CP的结构和开发新的抗体和检测方法来解决这些问题,包括一些粪便中NETs的检测方法。方法和发现:对有腹部症状的儿童进行常规和新方法的粪便提取。部分提取物经阴离子交换层析和大小排斥层析处理,部分用10种新的抗CP亚基S100A9的小鼠单克隆抗体进行elisa检测。采用抗dna或抗组蛋白包被微孔建立杂交elisa (HELISA),利用酶标记抗cp进行制备。通过离子交换色谱法,发现5 ~ 10个净电荷不同的粪便CP亚谱峰,它们都含有主要的染色质成分。DNA和组蛋白在钙保护蛋白之后出现在色谱组分中,表明NETs是在肠腔中产生的。新的CP单克隆对亚组分的反应非常不同,因此必须使用它们的混合物(称为MiMo)来获得可靠的粪便CP测定值。开发了一种称为FELISA的新方法,将标准品和样品直接应用于Nunc(丹麦)MaxiSorp板,不需要任何捕获抗体。它利用CP的特性在井中与塑料紧密结合。该方法具有较高的灵敏度,因为它可以检测到只有一个抗原表位的CP分子。它将为复杂的诊断程序提供更可靠的估计和更有效的患者选择。我们还开发了FELISA的替代方案:竞争性ELISA,其中包被微孔的S100A9将与标准品和样品中的CP竞争,以与适当稀释的hrp -抗CP溶液结合。在这种方法中,在萃取或稀释缓冲液中存在其他蛋白质不会干扰。使用HELISA,约65%的患者可检测到粪便NETs浓度在150至1500 ng/mL之间;然而,这些值与CP值相关性较差。用简单的TBS缓冲液和pH为5的5 mM EDTA提取粪便样品,产率约为90%,而商用试剂盒的产率未指定或在50%左右。粪便CP标准将使方法符合免疫测定的要求,即标准和样品中的CP结构必须相同。粪便阴离子交换组分的混合物作为标准可能是解决这个问题的一种方法。该原理在第一次试验中发挥了作用,将这种标准品在摄氏5度下储存4个月后仍能得到相同的值。结论:粪便CP由至少5个含有NETs或其降解产物的亚组分组成。商业试剂盒不应被接受用于临床,除非它已被证明可以检测所有可能需要使用单克隆混合物的亚组分。本文介绍的方法可用于这种质量控制。HELISA方法可用于测定粪便中的NETs,并研究其在肠道中可能的致病作用。使用FELISA和S100A9竞争性方法可以提高灵敏度,更高的精度,更好地选择患者进行更复杂的手术。
Heterogeneity of Fecal Calprotectin Reflecting Generation of Neutrophil Extracellular Traps (NETs) in the Gut: New Immunoassays Are Available
Background: We aimed at obtaining more information on the structure of fecal calprotectin (CP) as a basis for establishing improved quantitative assays and detection of Neutrophil Extracellular Traps (NETs) in stools. Commercial fecal CP assays produce different results, probably due to differences in antibodies, extraction procedures, and standards used. In addition, the structure of fecal CP may be different from that in the standard so that rules for immunoassays are violated. We aimed at solving these problems by studying the structure of fecal CP and developing new antibodies and assay procedures including some for NETs in stools. Methods and Findings: Stool samples from children with abdominal symptoms were extracted by a conventional and a new procedure. Some extracts were run on anion exchange and size exclusion chromatography, and fractions were tested on ELISAs by use of ten new mouse monoclonal antibodies against the CP subunit S100A9. Hybrid ELISAs (named HELISA) were established using anti-DNA or anti-histones for coating of microwells, and enzyme labelled anti-CP was used for development. By ion exchange chromatography, five to ten fecal CP subfraction peaks differing in net electric charge were found, all of which contained the major chromatin components. The presence of DNA and histones followed calprotectin in the chromatographic fractions suggesting that NETs are generated in the gut lumen. The new CP monoclonals reacted very differently against the subfractions so that a mixture of them (called MiMo) must be used to obtain reliable assay values for fecal CP. A new method called FELISA was developed where standards and samples are applied directly in Nunc (Denmark) MaxiSorp plates, without any catching antibody. It takes advantage of the property of CP to bind strongly to the plastic in wells. This method has a higher sensitivity because it will detect CP molecules with only one antigenic epitope available. It will give more reliable estimates and more efficient selection of patients for complex diagnostic procedures. We also developed an alternative to the FELISA: a competitive ELISA where S100A9 coated in microwells will compete with CP in standards and samples for binding to a properly diluted HRP-anti-CP solution. In this method, the presence of other proteins in extraction or dilution buffers will not interfere. Using the HELISA, about 65% of the patients had detectable fecal NETs in concentrations between 150 and 1500 ng/mL; however, the values correlated poorly with CP values. Extraction of fecal samples with a simple buffer of TBS, and pH 5 with 5 mM EDTA, gave a yield of about 90%, while the yields of commercial kits are not specified or lie around 50%. A fecal CP standard will bring methods in accordance with the requirements for immunoassays that the structure of CP in the standard and sample must be the same. A mixture of fecal anion exchange fractions as a standard may be a solution to this problem. The principle worked in the first trial by giving the same values after storage of such a standard at 5C for four months. Conclusions: Fecal CP consists of at least five subfractions containing NETs or degradation products thereof. Commercial kits should not be accepted for clinical use unless it has been shown that they can detect all subfractions which may require the use of a mixture of monoclonals. The methods presented here can be used for such a quality control. The HELISA methods can be used for assays on NETs in stools and to study their possible pathogenic effects in the gut. Use of the FELISA and the S100A9 competitive method may give increased sensitivity, higher precision, and better selection of patients for more complex procedures.